Instruction Manual

 

 

 

Controller 

 
 

 

Type: SV3-1-8Z 

 

 

 

 

 

 

 

 

 

 

 

 

 

BEIER-Electronic 

Winterbacher Str. 52/4, 73614 Schorndorf - Weiler 

Telefon 07181/46232, Telefax 07181/45732 

eMail: [email protected]   Internet: www.beier-electronic.de

Содержание SV3-1-8Z

Страница 1: ...uction Manual Controller Type SV3 1 8Z BEIER Electronic Winterbacher Str 52 4 73614 Schorndorf Weiler Telefon 07181 46232 Telefax 07181 45732 eMail info beier electronic de Internet www beier electron...

Страница 2: ...r 3 Safety Technical Indications for the User 4 General Description of the Device 5 Technical Data 6 Technical Data 7 Technical Data 8 Technical Data 9 Wiring Diagram 11 Technical Description 12 Techn...

Страница 3: ...Put controller back to use only if the faultless condition of the electrical equipment has been verified by an electrician In the case of disturbances in the electrical power supply the controller mu...

Страница 4: ...evice with the local mains voltage must be verified Set and connect plugs plug link slide switch according to technical description The set up is to be carried out by technically qualified personnel O...

Страница 5: ...or DC the SV3 1 8Z can be enabled or disabled This is very favorable in the case of applications with frequent switching operations e g level control because the control device doesn t have to be swit...

Страница 6: ...trol input 10 30V AC or DC potential free Insulation Voltage Input Output 0 5kV Inputs for proximity switches 5 inputs 10 30V DC Outputs 3 pnp outputs 24V DC max 0 5A 1 relay output 230V max 5A Time f...

Страница 7: ...ontroller SV3 1 8Z GB_Steuerger t SV3 1 8Z DOC 0710 BEIER Electronic 7 Typ SV3 1 8Z AC 110 230V 50 60Hz max 8A X1 X2 X0 X31 X32 X11 X41 X42 X1 X2 X21 X22 X12 X3 X3 X23 Q1 R1 H1 R2 H2 R3 H3 Technical D...

Страница 8: ...GB Controller SV3 1 8Z GB_Steuerger t SV3 1 8Z DOC 0710 BEIER Electronic 8 Technical Data...

Страница 9: ...ter X3 Umax1 Limitation of the maximum output voltage X1 Umax2 Limitation of the maximum output voltage X2 Umax3 Limitation of the maximum output voltage X3 H1 Status LED X1 H2 Status LED X2 H3 Status...

Страница 10: ...etting for soft run out X1 T2 1 Setting for soft start X2 T2 2 Setting for soft run out X2 T3 1 Setting for soft start X3 T3 2 Setting for soft run out X3 T41 Time function element T42 Time function e...

Страница 11: ...Wiring Diagram...

Страница 12: ...ave operation Pin 3 N Pin PE PE Pin assignment X3 Feeding device 3 Pin 1 full wave operation Pin 2 half wave operation Pin 3 N Pin PE PE Pin assignment X11 Control input Pin 1 free Pin 2 free Pin 3 10...

Страница 13: ...S3 and S5 Switch over between full and half wave operation by means of switch S1 S3 and S5 Sliding the switch in direction connecting plug as in the figure on page 9 then the full wave operation is ac...

Страница 14: ...to the minimum position 10 to the maximum performance possible Potentiometer for output voltage limitation Umax1 Umax2 and Umax3 With the potentiometer Umax1 Umax2 und Umax3 you can setup the maximum...

Страница 15: ...following device without T45 2 Control output X12 for following device with T45 Feeding device X1 without T44 3 Feeding device X1 with T44 Feeding device X2 without T43 4 Feeding device X2 with T43 F...

Страница 16: ...urrent has occurred LED dark No voltage supply Control input LED H11 This LED lights up when control input X11 is active Run LED H14 Flashes as soon as the time function elements are in function Seven...

Страница 17: ...edical high frequency devices VDE 0839 part 82 2 EN 50082 2 Electromagnetic Compatibility EMV 89 392 EEC EC Legal Provision Machines 89 336 EEC EC Legal Provision Electromagnetic Compatibility 73 23 E...