PF1350 TECHNICAL MANUAL REV 1 2/06/14
4.3 PERFORMANCE
VERIFICATION (continued)
4.3.2
Set the PF1351 front panel controls as follows:
RANGE =
Low
(0-135V)
VOLTS =
Fully
Counter
Clockwise
(CCW)
FREQ
=
60Hz
4.3.3
Set the variac to provide 120V AC to the DUT. Switch the DUT on and confirm the
displays is active and the cooling fans are on.
4.3.4
Adjust the DUT voltage to provide 100V output. Confirm an output of 60.0 Hz (+/- 0.1)
using the wattmeter.