Caution 

Access to the control box and to all other electrical parts during installation and/or 
maintenance work is only permitted for qualified specialists

 

 

 

4.3  Procedure by lamp bursting and breakage of glass 

In case of lamp bursting glass shelves, sneeze screen, front and lateral glasses, proceed 
immediately as follows: 

 

Switch off the appliance and close the counter. 

 

Self-service counter: Avoid guests taking food contaminated with glass splinters. 

 

Collect and replace all plates filled with food of guests, who have been nearby when the 
incident happened. 

 

Take out all food containers of the counter. Dispose food in rubbish bin (not in bin for 
leftovers). 

 

Take off shatter protection glass of defective lamp and clean it. 

 

Clean the appliance and its environment (counter and floor). 

 

Replace broken items. 

 

Refit shatter protection glass with bracket. 

 

Refill counter. 

 

Counter is ready for reopening. 

4.4  Glazing/Danger of accident 

Beer counters are equipped with one sheet safety glass (ESG). 

Incorrectly, badly mounted or damaged panels may fall out and cause serious injuries. Be 
sure to check all glazing before opening the self-service counter, but also after cleaning the 
glass (especially the front- glass) that: 

 

The  panel  or  shield  is  placed  properly  e.g.: In the  lower  glass  holders  in  the  intended 
slots (not in the rack separations, nor the discontinued racks). Both sides in the above 
designed mounted holders. 

 

The panels have no damage 

(damaged edges and corners = cut risk and insufficient 

support)

.  The  safety  glass  may  crack  or  burst  due  to  internal  tension,  even  without  

contact with the damaged edge. 

 

The glass holder is not damaged and the upper front holder (customer side) is well fitted. 
(Upper part must rest on the upper glass edge). These holders are glued. Loose holders 
must be reglued by qualified personnel. If the glass holder moves upwards, the upper 
stop ridge (arrest) of the front panel may be affected and the panel may fall out if struck. 

 

 

Содержание Uno Top Cold

Страница 1: ...Uno Top Cold The world s most compact refrigerated showcase system Operation Manual Installation Technical Specifications...

Страница 2: ...4 4 Glazing Danger of accident 8 5 Warranty and liabilities 9 6 Transport of Uno Top Cold 10 7 Packaging of Uno Top Cold 10 8 Installation of Uno Top Cold 11 8 1 Setting up and moving the device 11 8...

Страница 3: ...efully read these installation and operating instructions before installing the appliance and putting it into service and strictly follow the notices herein thus contributing to keeping the appli ance...

Страница 4: ...enance Therefore the operations manager and the operators must read the entire manual before the unit is installed and put into operation The manual must always be kept close to the unit and easily ac...

Страница 5: ...s of the appliance or the use of individual spare parts and especially parts essential for the functioning of the appliance that are not original Beer Grill parts as well as non adherence to notes in...

Страница 6: ...count may the safety installations be altered Warning signals placed directly on the device must be strictly observed at all times The device must be checked and serviced regularly at least once per y...

Страница 7: ...technology electrical installation and mechanical work Any alteration must be authorized by the manufacturer in order to maintain warranty Those covers bearing a warning may only be opened by speciali...

Страница 8: ...nvironment counter and floor Replace broken items Refit shatter protection glass with bracket Refill counter Counter is ready for reopening 4 4 Glazing Danger of accident Beer counters are equipped wi...

Страница 9: ...operating and servicing of the unit Operating the unit with defective safety devices or safety devices which have not been installed properly and are not in working condition Disregard of the referen...

Страница 10: ...g complaint period For transport please note the following points When transporting ensure that the pallet is secured against slippage and tipping Always transport the packaged device upright and do n...

Страница 11: ...re The appliances are equipped with electronic controls and ventilation Please take care that no equipment with substantial emanations of heat grease or steam griddles deep fryers bain maries etc are...

Страница 12: ...in creases operating costs 8 2 Preparation at the installation site Ensure that furniture cladding and counters are prepared according to the technical specifications Compare the operating voltage on...

Страница 13: ...socket must be accessible after mounting or installation of the equipment Replacement of the cable must be carried out only by the manufacturer service techni cian or authorized dealer 10 Start up Ope...

Страница 14: ...e documented in detail in the operating manual The following principles apply As an optimum the products in Uno Top Cold can maintain the temperatures at which they were put into the counter Repeatedl...

Страница 15: ...igeration unit is switched on and off by the green toggle switch The digital temperature display of the cooling areas is located above the switches The screen displays the average temperature and the...

Страница 16: ...pending on the surrounding temperature and humidity the interior temperature is not to be set too low as this could lead to icing on exposed areas of the cooling element This will interfere with the c...

Страница 17: ...sing the UP key you can easily switch from AP0 to AP6 and thus select the simplified parameter list ring list Step 4 Select sensor type o06 The display automatically shows sensor parameter selection o...

Страница 18: ...DOWN keys to show the parameter list To select a pre installed application configure the parameter o61 Press SET to gain access to the parameter o61 Use the UP DOWN keys to select an application AP0...

Страница 19: ...ess DEFROST for 3 seconds to stop manual defrosting The DEFROST symbol is displayed during defrosting Displaying an active alarm Press QUICK COOLING for 3 seconds to start quick cooling Pud stands for...

Страница 20: ...abrasive sponges must not be used as these can damage the metal surfaces or covers The unit has to be cleaned daily Wear acid proof gloves while cleaning the parts to prevent skin irritations After cl...

Страница 21: ...le detergents Never use sharp edged or metallic tools like steel wool or scrubbing cleanser for cleaning The floor under the device must not be cleaned with corrosive cleaning agents since vapours cou...

Страница 22: ...ons wherever possible disconnect the device from the power supply beforehand Both repairs and or exchange of components could prove to be necessary All defective parts have to be exchanged exclusively...

Страница 23: ...r to the Front if touched 12 5 In case of malfunctions Before requesting service please check the mains connection and the fuses and check the following points If the cooling unit does not work at all...

Страница 24: ...the error please contact customer service 13 Disposal At the end of its service life the device must be disconnected form the power supply before dismantling the individual components Here it must be...

Страница 25: ...ger function properly In this case the appliance must be repaired by a qualified technician or by the Beer Grill customer service When contacting after sales service always indicate serial number and...

Страница 26: ...00 K rnerstrasse 14 a Tel 49 0 71 61 659 876 info beergrill com CH 5612 Villmergen Fax 41 0 56 618 7849 D 79539 L rrach Fax 49 0 71 61 659 879 www beergrill com Seite 26 15 Appendix Drawing No 63Ma081...

Страница 27: ...Subject to change without notice 63Ma081 00 UNO Top Cold GN 1 1 100 Ausf hrung gerade Ex cution plane Straight version 06 10 2017 M B sch 1 7 1 1 Format A3 359 315 30 10 6 657 Bedienerseite C t op ra...

Страница 28: ......

Отзывы: