Installation of Uno Top Cold 

8.1  Setting up and moving the device 

 

Solid substructure 

The  devices  are  not  self-supporting,  that  means,  tabletop  and  built-in  models  need  a 
solid base for transport and installation with the dimensions corresponding to those of 
the devices. 

 

Lifting 

Lifting  the  device  (weight)  off  the  pallet  must  at  all  costs  be  carried  out  with  suitable 
equipment. 

 

Using a fork-lift truck 

When  using  a  fork-lift  truck,  it  is  imperative  to  ensure  that  the  electrical  power-supply 
cable does not become wedged or damaged. 

Always  lift  and  transport  the  device  from  underneath  on  the  longitudinal  side  with  
assisting devices. 

 

Moving 

After every time the device has been moved, a visual inspection of possible damage to 
the  electrical  cable  must  be  made.  In  the  event  of  damage,  the  device  must  not  be  
connected to the mains power supply. 

 

Ambient temperature 

The appliances are equipped with electronic controls and ventilation. Please take care 
that no equipment with substantial emanations of heat, grease or steam (griddles, deep 
fryers, bain-maries, etc.) are installed and operated nearby. 

 

Built-in units 

The appliances may only be installed by qualified and authorized experts.  

When installing units in a niche or cut out of a table top you have to assure the airflow of 
the  forced  air-circulation.  For  handling  and  thermal  reasons  we  recommend  the  first  
version. 

 

Glasses 

Ensure that all glasses are correctly positioned and placed. 

 

Installation site and storage

 

The appliances contain electronic components that may not be stored in cold and humid 
areas. Make sure that no condensate water can form during storage. 

If an appliance has been out of service for a prolonged time and has been stored in a 
cool or humid area, it must be thoroughly checked before restarting. 

Contact  with  salt  water  is  strictly  forbidden. If  an  appliance  is  installed  at  a  swimming 
pool, it is essential to assure that the equipment does not get in contact with substances  
containing  chlorine  or  acids  that  may  affect  the  anti-corrosive  protection  of  the  metal  
construction. 

In addition: 

- do not expose to any aggressive media 

 

- protect from solar radiation 

 

- avoid mechanical vibrations 

 

Содержание Uno Top Cold

Страница 1: ...Uno Top Cold The world s most compact refrigerated showcase system Operation Manual Installation Technical Specifications...

Страница 2: ...4 4 Glazing Danger of accident 8 5 Warranty and liabilities 9 6 Transport of Uno Top Cold 10 7 Packaging of Uno Top Cold 10 8 Installation of Uno Top Cold 11 8 1 Setting up and moving the device 11 8...

Страница 3: ...efully read these installation and operating instructions before installing the appliance and putting it into service and strictly follow the notices herein thus contributing to keeping the appli ance...

Страница 4: ...enance Therefore the operations manager and the operators must read the entire manual before the unit is installed and put into operation The manual must always be kept close to the unit and easily ac...

Страница 5: ...s of the appliance or the use of individual spare parts and especially parts essential for the functioning of the appliance that are not original Beer Grill parts as well as non adherence to notes in...

Страница 6: ...count may the safety installations be altered Warning signals placed directly on the device must be strictly observed at all times The device must be checked and serviced regularly at least once per y...

Страница 7: ...technology electrical installation and mechanical work Any alteration must be authorized by the manufacturer in order to maintain warranty Those covers bearing a warning may only be opened by speciali...

Страница 8: ...nvironment counter and floor Replace broken items Refit shatter protection glass with bracket Refill counter Counter is ready for reopening 4 4 Glazing Danger of accident Beer counters are equipped wi...

Страница 9: ...operating and servicing of the unit Operating the unit with defective safety devices or safety devices which have not been installed properly and are not in working condition Disregard of the referen...

Страница 10: ...g complaint period For transport please note the following points When transporting ensure that the pallet is secured against slippage and tipping Always transport the packaged device upright and do n...

Страница 11: ...re The appliances are equipped with electronic controls and ventilation Please take care that no equipment with substantial emanations of heat grease or steam griddles deep fryers bain maries etc are...

Страница 12: ...in creases operating costs 8 2 Preparation at the installation site Ensure that furniture cladding and counters are prepared according to the technical specifications Compare the operating voltage on...

Страница 13: ...socket must be accessible after mounting or installation of the equipment Replacement of the cable must be carried out only by the manufacturer service techni cian or authorized dealer 10 Start up Ope...

Страница 14: ...e documented in detail in the operating manual The following principles apply As an optimum the products in Uno Top Cold can maintain the temperatures at which they were put into the counter Repeatedl...

Страница 15: ...igeration unit is switched on and off by the green toggle switch The digital temperature display of the cooling areas is located above the switches The screen displays the average temperature and the...

Страница 16: ...pending on the surrounding temperature and humidity the interior temperature is not to be set too low as this could lead to icing on exposed areas of the cooling element This will interfere with the c...

Страница 17: ...sing the UP key you can easily switch from AP0 to AP6 and thus select the simplified parameter list ring list Step 4 Select sensor type o06 The display automatically shows sensor parameter selection o...

Страница 18: ...DOWN keys to show the parameter list To select a pre installed application configure the parameter o61 Press SET to gain access to the parameter o61 Use the UP DOWN keys to select an application AP0...

Страница 19: ...ess DEFROST for 3 seconds to stop manual defrosting The DEFROST symbol is displayed during defrosting Displaying an active alarm Press QUICK COOLING for 3 seconds to start quick cooling Pud stands for...

Страница 20: ...abrasive sponges must not be used as these can damage the metal surfaces or covers The unit has to be cleaned daily Wear acid proof gloves while cleaning the parts to prevent skin irritations After cl...

Страница 21: ...le detergents Never use sharp edged or metallic tools like steel wool or scrubbing cleanser for cleaning The floor under the device must not be cleaned with corrosive cleaning agents since vapours cou...

Страница 22: ...ons wherever possible disconnect the device from the power supply beforehand Both repairs and or exchange of components could prove to be necessary All defective parts have to be exchanged exclusively...

Страница 23: ...r to the Front if touched 12 5 In case of malfunctions Before requesting service please check the mains connection and the fuses and check the following points If the cooling unit does not work at all...

Страница 24: ...the error please contact customer service 13 Disposal At the end of its service life the device must be disconnected form the power supply before dismantling the individual components Here it must be...

Страница 25: ...ger function properly In this case the appliance must be repaired by a qualified technician or by the Beer Grill customer service When contacting after sales service always indicate serial number and...

Страница 26: ...00 K rnerstrasse 14 a Tel 49 0 71 61 659 876 info beergrill com CH 5612 Villmergen Fax 41 0 56 618 7849 D 79539 L rrach Fax 49 0 71 61 659 879 www beergrill com Seite 26 15 Appendix Drawing No 63Ma081...

Страница 27: ...Subject to change without notice 63Ma081 00 UNO Top Cold GN 1 1 100 Ausf hrung gerade Ex cution plane Straight version 06 10 2017 M B sch 1 7 1 1 Format A3 359 315 30 10 6 657 Bedienerseite C t op ra...

Страница 28: ......

Отзывы: