19
Lift folding evaporator cover.
Evaporator uncovered, slightly iced up.
Sensor 1 must always be placed before
the grille in this way.
Rear evaporator mount.
Lift rear side of evaporator.
Only lift evaporator in this position, then
clean underneath.
Folding evaporator
The interior cooling evaporator can be folded upwards for cleaning and secured in its upper position by
a lateral latch.
Some cooling cabinets are fitted with pneumatic springs that hold the evaporator in its upper during
cleaning or maintenance. It the pneumatic springs weaken and longer safely hold the evaporator in the
upper position, they must be replaced immediately by a qualified service person.
11.4 Cleaning ventilation channel next to rear door
To unhook ventilation channel at rear
door
→ first lift it, then slide it out.
Ventilation channel at rear door must
be securely latched again.