3.3 

Security guidelines 

All safety regulations were followed during manufacturing, particularly international CEE regulations. The 
appliance was subject to a comprehensive final check at the plant. 

 

 

The appliance may only be operated in a technically acceptable condition and in ac-
cordance with all regulations, safety regulations and conscious of risks with regard to 
the operating instructions! Any other uses beyond those intended are to be considered 
as not being in compliance with the regulations. The manufacturer / supplier is not liable 
for  any  damages  resulting  from  such  actions.  The  user  bears  the  entire  risk.  Use  in 
accordance  with  the  regulations  includes  observance  of  the mounting  and  operating 
instructions and keeping with the inspection and maintenance regulations.

 

Hazard warnings 

4.1 

Electrical energy 

 

 

Attention,

  switch  off  the  appliance  immediately  in  case  of  interruptions  of  power  

supply! 

 

Any work carried out on the electrical units or utilities may only be performed in accordance with electri-
cal regulations by a qualified electrician or by a person instructed and supervised by a qualified electri-
cian.  

Appliances and unit components which are subject to inspection, maintenance and repair work have to 
be completely disconnected from the power source and free of voltage. First, check as to whether the 
activated parts have indeed been disconnected and are voltage-free, then ground and short them out. 
Insulate any adjacent parts that are also energized! 

4.2 

General safety instructions 

The connection and any technical adaptations of the appliance must be carried out by specialists! 
This is especially valid for any work on the cooling technology, electrical installation, water connec-
tion and mechanical work. 

Any alteration must be authorized by the manufacturer in order to maintain warranty. 

Covers may only be opened by specialists. 

Protective covers and devices may not be removed due to risk of injury. 

The control system may only be opened by an authorised specialist. 

Air currents near the refrigerating unit resulting from improperly installed ventilation or draughts are 
to be avoided, in order to ensure the efficient functioning of the refrigerating unit. 

Содержание Beer Cold Rack

Страница 1: ...Beer Cold Rack Refrigerated self service showcase for convenience food Operating instructions Installation Technical Data...

Страница 2: ...ay 12 10 4 Setting the temperature 13 10 5 Manual defrosting 13 10 6 Lighting 13 10 7 Recirculating air cooling 14 10 8 Full performance of the cooling unit 15 10 9 Daily work with the cooling device...

Страница 3: ...us contributing to keeping the appliance in a perfect and func tioning state Due to ongoing development illustrations operating steps and technical data may slightly differ from the supplied equipment...

Страница 4: ...he unit and easily accessible Beer Grill AG cannot assume any responsibility or warranty obligations for any damage sustained due to non adherence to the installation and operating instructions or due...

Страница 5: ...al spare parts and especially parts essential for the functioning of the appliance that are not original Beer Grill parts as well as non adher ence to notes in the operating manual will cause the laps...

Страница 6: ...ccordance with electri cal regulations by a qualified electrician or by a person instructed and supervised by a qualified electri cian Appliances and unit components which are subject to inspection ma...

Страница 7: ...ts who have been nearby when the incident happened Take out all food containers of the counter Dispose food in rubbish bin not in bin for leftovers Clean the appliance and its environment counter and...

Страница 8: ...e of wear and tear parts Unauthorized repairs Force majeure Beer Grill AG grants a one year guarantee on all parts of the Beer Cold Rack provided that the damage has not been caused by improper handli...

Страница 9: ...contact our customer service 8 Set up The following points must be observed when setting up the appliances Solid substructure Make sure your cooling units stand securely on a level surface Make sure...

Страница 10: ...tor and reduce the cooling power of the system Condensate disposal As your appliance is operated in an open area the daily amount of condensation water can reach 10 litres This must be drained off in...

Страница 11: ...information please refer to the electrical diagram in the appendix 10 Start up Operating instructions 10 1 Intended use Cold Rack and cooling units are complete counters with glazed open structure Th...

Страница 12: ...ludes observance of the mounting and op erating instructions and keeping with the inspection and maintenance regulations Any changes to the appliance is to be made solely by the manufacturer 10 3 Cont...

Страница 13: ...se Before the cooling units are filled please wait until the desired temperature has been reached Depending on the surrounding temperature and humidity the interior temperature is not to be set too lo...

Страница 14: ...is cooled down and blown into the goods area through an incoming air duct 3 The heat drawn off from the interior is dissipated to the environment via the cooling unit 4 5 However this mode of operatio...

Страница 15: ...matic defrosting is performed every 2 to 3 hours That a temperature peak is recorded every 2 to 3 hours That this temperature peak is a consequence of the automatic defrosting 10 9 Daily work with the...

Страница 16: ...on below the price label holder 10 11 Fitting the price label holder Price label holder clicked on Lift price label holder up Lift protective foil and pull it slightly out Keep the protective foil li...

Страница 17: ...tainless steel surface clean Make sure that there is always enough fresh air on the surface Never touch the surface with rusty material 11 2 Cleaning agents Glass cleaner The surface of the display is...

Страница 18: ...or acids 11 3 Cleaning the cooling tub Remove the inner tub inner well and side panel from the refrigeration well and tilt the evaporator then sway the lock to the left Now the evaporator is fixed an...

Страница 19: ...g and secured in its upper position by a lateral latch Some cooling cabinets are fitted with pneumatic springs that hold the evaporator in its upper during cleaning or maintenance It the pneumatic spr...

Страница 20: ...the supports can be hooked on level or at an angle When assembling the shelf panel must be inserted into the notch of the sup port Finally firmly replace the plug con nector of the LED lighting The e...

Страница 21: ...e 12 1 Optimal product presentation In order to guarantee efficient operation of the refrigerated well along with optimum presentation of the goods the entire technological equipment has to be checked...

Страница 22: ...switch been turned on Have the electronics been set incorrectly If the cooling device is working but incorrect the products are too warm or too cold please check the following points before contacting...

Страница 23: ...sensor F4 E4H Sensor F4 error break Control of the sensor F4 E5 Door open too long Close the door E6 High pressure malfunction Check condenser fan function and radiator lamellae for dirt E7 Low press...

Страница 24: ...onger function properly In this case the appliance must be repaired by a qualified technician or by the Beer Grill customer service Check the mains cable and fuses beforehand When contacting the custo...

Страница 25: ...25 14 Appendix Drawing 52Ma009 00 Installation instructions Drawing 52Ma012 20 GN 2 1 EK mobile model Drawing 52Ea199 40 Electrical diagram...

Страница 26: ...tellectual property of Beer Grill AG 5612 Villmergen Switzerland Passing it on to third parties and or reproducing it in any way are prohibited without authorisation from Beer Grill AG Massstab R1 R2...

Страница 27: ...fications Subject to change without notice 52Ma012 20 GN 2 1 EK mit R ckwand Cold Rack Fahrmodell Cold Rack Mod le mobile Cold Rack Mobile model 05 10 2018 U Meier 1 15 1 1 Format A3 600 770 1980 1280...

Страница 28: ......

Отзывы: