BEER Beer Cold Rack Скачать руководство пользователя страница 21

 

 

 

21

 

Never clean the rear or the bottom of the tub with a water hose or a scrubber. Avoid running water 
near this areas. 

All other surfaces can be cleaned with soft detergents or water. 

If the condenser is dirty, clean it with a broom or a vacuum cleaner.

 

 

 

Attention

, only work vertically, to avoid bending the lamellae!

 

Do not close or put any objects in front of the condenser openings for fresh air because 
otherwise the refrigerating efficiency will be reduced. 

 

 

 

After all cleaning has been completed the cooling device has to be returned to its orig-
inal state in order to guarantee efficient operation! 

In  addition  to  daily  cleaning,  service  and  maintenance  of  the  cooling  devices  are  
required to be carried out in regular intervals by qualified specialists. 

12  Maintenance 

12.1  Optimal product presentation 

In order to guarantee efficient operation of the refrigerated well along with optimum presentation of the 
goods, the entire technological equipment has to be checked and maintained regularly. 

The following should be done: 

Complete cleaning of the entire cooling unit. 

Checking the ventilator for functionality. 

Checking the thermostat setting. 

Checking the temperature of the drop-in refrigerated well: The exhaust air temperature directly be-
neath and inside the rear ventilation channel must not be higher than 3°C. 

Checking and cleaning the drainage lines, drip water container and drip water evaporation. 

Checking the gas spring on the evaporator. 

Cleaning the condensers on the cooling unit. 

Checking the amount of refrigerant. 

Making a security check of the unit. 

 

 

We recommend to have your appliance serviced annually by a refrigeration expert. On 
request  we  can  provide  you  with  addresses  but  you  may  also  contact  our  customer 
service. 

Содержание Beer Cold Rack

Страница 1: ...Beer Cold Rack Refrigerated self service showcase for convenience food Operating instructions Installation Technical Data...

Страница 2: ...ay 12 10 4 Setting the temperature 13 10 5 Manual defrosting 13 10 6 Lighting 13 10 7 Recirculating air cooling 14 10 8 Full performance of the cooling unit 15 10 9 Daily work with the cooling device...

Страница 3: ...us contributing to keeping the appliance in a perfect and func tioning state Due to ongoing development illustrations operating steps and technical data may slightly differ from the supplied equipment...

Страница 4: ...he unit and easily accessible Beer Grill AG cannot assume any responsibility or warranty obligations for any damage sustained due to non adherence to the installation and operating instructions or due...

Страница 5: ...al spare parts and especially parts essential for the functioning of the appliance that are not original Beer Grill parts as well as non adher ence to notes in the operating manual will cause the laps...

Страница 6: ...ccordance with electri cal regulations by a qualified electrician or by a person instructed and supervised by a qualified electri cian Appliances and unit components which are subject to inspection ma...

Страница 7: ...ts who have been nearby when the incident happened Take out all food containers of the counter Dispose food in rubbish bin not in bin for leftovers Clean the appliance and its environment counter and...

Страница 8: ...e of wear and tear parts Unauthorized repairs Force majeure Beer Grill AG grants a one year guarantee on all parts of the Beer Cold Rack provided that the damage has not been caused by improper handli...

Страница 9: ...contact our customer service 8 Set up The following points must be observed when setting up the appliances Solid substructure Make sure your cooling units stand securely on a level surface Make sure...

Страница 10: ...tor and reduce the cooling power of the system Condensate disposal As your appliance is operated in an open area the daily amount of condensation water can reach 10 litres This must be drained off in...

Страница 11: ...information please refer to the electrical diagram in the appendix 10 Start up Operating instructions 10 1 Intended use Cold Rack and cooling units are complete counters with glazed open structure Th...

Страница 12: ...ludes observance of the mounting and op erating instructions and keeping with the inspection and maintenance regulations Any changes to the appliance is to be made solely by the manufacturer 10 3 Cont...

Страница 13: ...se Before the cooling units are filled please wait until the desired temperature has been reached Depending on the surrounding temperature and humidity the interior temperature is not to be set too lo...

Страница 14: ...is cooled down and blown into the goods area through an incoming air duct 3 The heat drawn off from the interior is dissipated to the environment via the cooling unit 4 5 However this mode of operatio...

Страница 15: ...matic defrosting is performed every 2 to 3 hours That a temperature peak is recorded every 2 to 3 hours That this temperature peak is a consequence of the automatic defrosting 10 9 Daily work with the...

Страница 16: ...on below the price label holder 10 11 Fitting the price label holder Price label holder clicked on Lift price label holder up Lift protective foil and pull it slightly out Keep the protective foil li...

Страница 17: ...tainless steel surface clean Make sure that there is always enough fresh air on the surface Never touch the surface with rusty material 11 2 Cleaning agents Glass cleaner The surface of the display is...

Страница 18: ...or acids 11 3 Cleaning the cooling tub Remove the inner tub inner well and side panel from the refrigeration well and tilt the evaporator then sway the lock to the left Now the evaporator is fixed an...

Страница 19: ...g and secured in its upper position by a lateral latch Some cooling cabinets are fitted with pneumatic springs that hold the evaporator in its upper during cleaning or maintenance It the pneumatic spr...

Страница 20: ...the supports can be hooked on level or at an angle When assembling the shelf panel must be inserted into the notch of the sup port Finally firmly replace the plug con nector of the LED lighting The e...

Страница 21: ...e 12 1 Optimal product presentation In order to guarantee efficient operation of the refrigerated well along with optimum presentation of the goods the entire technological equipment has to be checked...

Страница 22: ...switch been turned on Have the electronics been set incorrectly If the cooling device is working but incorrect the products are too warm or too cold please check the following points before contacting...

Страница 23: ...sensor F4 E4H Sensor F4 error break Control of the sensor F4 E5 Door open too long Close the door E6 High pressure malfunction Check condenser fan function and radiator lamellae for dirt E7 Low press...

Страница 24: ...onger function properly In this case the appliance must be repaired by a qualified technician or by the Beer Grill customer service Check the mains cable and fuses beforehand When contacting the custo...

Страница 25: ...25 14 Appendix Drawing 52Ma009 00 Installation instructions Drawing 52Ma012 20 GN 2 1 EK mobile model Drawing 52Ea199 40 Electrical diagram...

Страница 26: ...tellectual property of Beer Grill AG 5612 Villmergen Switzerland Passing it on to third parties and or reproducing it in any way are prohibited without authorisation from Beer Grill AG Massstab R1 R2...

Страница 27: ...fications Subject to change without notice 52Ma012 20 GN 2 1 EK mit R ckwand Cold Rack Fahrmodell Cold Rack Mod le mobile Cold Rack Mobile model 05 10 2018 U Meier 1 15 1 1 Format A3 600 770 1980 1280...

Страница 28: ......

Отзывы: