PN 4277248DD
GLOSSARY-4
GLOSSARY
CLSI
Clinical and Laboratory Standard Institute formerly known as the National
Committee for Clinical Laboratory Standards (NCCLS).
cm
Centimeter, a unit of linear measurement.
Codes
On windows and printouts, symbols, such as -----, ++++, :::::, appear with or in
place of sample or control results because of irregularities. A code can only be
generated by the instrument.
Coefficient of
Variation
An expression, in percent, of data spread as related to the mean.
%CV = (SD/Mean) x 100
Coincidence
More than one cell within aperture-sensing boundaries at the same time. The
system counts only one pulse and automatically corrects results for
coincidence.
Collation
The process of combining the results of different test modes(CBC/Diff and
Retic) analyzed from the same sample.
Command Center
A teal bar that appears at the bottom of the screen.
Control Disk
A data diskette that contains the assay values for the lot number of the control
being used.
Coulter Principle
A method of counting and sizing cells by detecting and measuring changes in
electrical resistance when a particle in a conductive liquid goes through a small
aperture.
Critical Limits
Values established by your laboratory to flag results requiring immediate action.
CSA
Canadian Standards Association.
CSF
Cerebrospinal fluid is a clear, colorless, non-cellular fluid that circulates over
the brain and spinal cord.
Cursor
On the screen, a place shown by a little blinking indicator or by a highlighted
area. The cursor shows where you can select an option or type information.
CV (Coefficient of
Variation)
An expression, in percent, of data spread as related to the mean.
%CV = (SD/Mean) x 100
Cycle Counter
A number that appears on the Analyzer MAIN MENU screen that represents the
actual number of instrument cycles that have occurred.
DataPlot
A graphic representation of results. DataPlots present a combined view of
population density and membership. Colors represent different types of cells.
Shades of colors represent the number of cells--bright colors are the most dense.
Data Management
System (DMS)
The computer hardware and software that controls instrument operation;
displays, stores, and recalls sample data; automates QC and calibration
procedures; and assists you in troubleshooting.
Also called: ADMS, DMS, LH Workstation.
Default
A setting the instrument uses automatically. For example, you can set up a
default printer. Every time you print sample results, the Workstation
automatically prints the sample results to the default printer.
Содержание COULTER LH 750 System
Страница 26: ...PN 4277248DD 1 12 USE AND FUNCTION MATERIAL SAFETY DATA SHEETS MSDS ...
Страница 54: ...PN 4277248DD 3 22 OPERATION PRINCIPLES XB ANALYSIS ...
Страница 84: ...PN 4277248DD 4 30 SPECIFICATIONS CHARACTERISTICS BAR CODE LABEL SPECIFICATIONS ...
Страница 90: ...PN 4277248DD 5 6 HAZARDS DISPOSAL OF ELECTRICAL INSTRUMENTATION ...
Страница 116: ...PN 4277248DD 6 INDEX INDEX X XB Analysis definition GLOSSARY 16 XM Analysis definition GLOSSARY 16 ...
Страница 118: ......