Operation
EL6910
126
Version: 1.8.0
LED Display
State 1
State 2
State 3
State 4
Meaning
Off
Off
Off
lit
No TwinSAFE project available on the component
Off
Off
lit
lit
TwinSAFE project loaded, but not yet in RUN state
lit
Off
lit
lit
TwinSAFE project loaded and in RUN state.
Customization is active for at least one TwinSAFE group
lit
lit
lit
lit
TwinSAFE project loaded and in RUN state.
Customization is NOT active
4.18.3
Diagnostic objects
CAUTION
Do not change CoE objects!
Do not make any modifications to the CoE objects in the TwinSAFE components! Any modifications (e.g.
using TwinCAT) of the CoE objects will permanently set the TwinSAFE components to the Fail-Stop state.
Index F984
hex
: Device Info Data C1
CoE object F984
hex
currently displays internal temperature and voltage values for the TwinSAFE component.
Index
Name
Meaning
Flags Default
F984:01
Voltage C2
Voltage µC2
RO
0
dec
F984:02
Temperature C1
Temperature µC1
RO
0
dec
Index F985
hex
: Device Info Data C2
CoE object F985
hex
currently displays internal temperature and voltage values for the TwinSAFE component.
Index
Name
Meaning
Flags
Default
F985:01
Voltage C1
Voltage µC1
RO
0
dec
F985:02
Temperature C2
Temperature µC2
RO
0
dec
Diagnostics history
Any errors, which occur during operation of the TwinSAFE component, such as overtemperature or
undervoltage, are entered in the diagnostics history with a corresponding timestamp.
Index F100
hex
: FSLOGIC status
The CoE object F100
hex
shows the current status of the TwinSAFE component.
Index
Name
Meaning
Flags Default
F100:01 Safe Logic
State
Status of the internal logic:
0: OFFLINE
1: RUN
2: STOP
3: SAFE
4: ERROR
6: START
8: PREPARE
10: RESTORE
11: PROJECT-CRC-OK
RO
0
bin
F100:02 Cycle Counter
Life cycle counter, which is incremented with each TwinSAFE
logic cycle.
RO
0
bin
This CoE object is additionally copied into the cyclic process image of the TwinSAFE component. From
there, this information can be directly linked into the PLC.
Содержание TwinSAFE EL6910
Страница 1: ...Operation Manual for EL6910 TwinSAFE Logic Terminal 1 8 0 2019 01 09 Version Date...
Страница 2: ......
Страница 62: ...Operation EL6910 62 Version 1 8 0 Fig 63 Check Safe Addresses context menu Fig 64 Check Safe Addresses dialog...
Страница 69: ...Operation EL6910 69 Version 1 8 0 Fig 73 The Safety Project Online View tab...
Страница 71: ...Operation EL6910 71 Version 1 8 0 Fig 75 Group Status Online ERROR Fig 76 Group Status Online STOP...
Страница 136: ...Appendix EL6910 136 Version 1 8 0 5 2 Certificates...
Страница 137: ...Appendix EL6910 137 Version 1 8 0...