4.18
Diagnostics
4.18.1
Diagnostic LEDs
The LEDs Diag 1 to Diag 4 display diagnostic information for the EL6910.
Fig. 176: EL6910 diagnostic LEDs
4.18.1.1
LED indicators
Diagnostic LEDs
LED
lit
flashing
off
Diag 1
(green)
Environment variables,
operating voltage and internal
tests are in the valid range
• If Diag 2 flashes, a logic
error code applies
-
Environment variables,
operating voltage and internal
tests are outside the valid
range
• If Diag 2 flashes, an
environment error code
applies
Diag 2
(red)
Together with Diag 3 and 4:
Global shutdown
1)
has
occurred. (see diag history of
the TwinSAFE components)
Logic or environment error
code according to Diag1 and
tables below is output
Together with Diag 3 and 4:
Global fault
1)
has occurred. (see
diag history of the TwinSAFE
components)
Diag 3
(red)
Global fault or global shutdown
on µC1
1)
-
No global fault or global
shutdown on µC1
1)
Diag 4
(red)
Global fault or global shutdown
on µC2
1)
-
No global fault or global
shutdown on µC2
1)
1. A global fault permanently disables the TwinSAFE component, so that it has to be replaced. A global
shutdown temporarily disables the TwinSAFE component. The error can be reset by switching off and
back on again.
Содержание TwinSAFE EL6910
Страница 1: ...Operation Manual for EL6910 TwinSAFE Logic Terminal 1 8 0 2019 01 09 Version Date...
Страница 2: ......
Страница 62: ...Operation EL6910 62 Version 1 8 0 Fig 63 Check Safe Addresses context menu Fig 64 Check Safe Addresses dialog...
Страница 69: ...Operation EL6910 69 Version 1 8 0 Fig 73 The Safety Project Online View tab...
Страница 71: ...Operation EL6910 71 Version 1 8 0 Fig 75 Group Status Online ERROR Fig 76 Group Status Online STOP...
Страница 136: ...Appendix EL6910 136 Version 1 8 0 5 2 Certificates...
Страница 137: ...Appendix EL6910 137 Version 1 8 0...