Configuration software KS2000
KL3361 and KL3362
41
Version: 2.2.0
Enable
Connect the lower input of the And gate with the desired function in order to specify when the And gate
should switch through a trigger pulse (
).
Always enabled
The trigger pulse is always switched through.
Digital input High
The trigger pulse is switched through, if the trigger input (24 V
trigger) of the oscilloscope terminal is on High potential.
Analog input 1 above
switching threshold
The trigger pulse is switched through, if the signal at analog input 1
of the oscilloscope terminal increases above the switching
threshold 2. The threshold level can be specified via the
tab.
(KL3362 only)
Analog input 2 above
switching threshold
The trigger pulse is switched through, if the signal at analog input 2
of the oscilloscope terminal increases above the switching
threshold 2. The threshold level can be specified via the
tab.
Digital input Low
The trigger pulse is switched through, if the trigger input (24 V
trigger) of the oscilloscope terminal is on Low potential.
Analog input 1 below
switching threshold
The trigger pulse is switched through, if the signal at analog input 1
of the oscilloscope terminal decreases below the specified
switching threshold 2. The threshold level can be specified via the
(KL3362 only)
Analog input 2 below
switching threshold
The trigger pulse is switched through, if the signal at analog input 2
of the oscilloscope terminal decreases below the specified
switching threshold 2. The threshold level can be specified via the
Action
Connect the output of the And gate with the desired function in order to specify which task should be
triggered.
Reset the timer
(chronometer) to zero
(
)
Resets the timer back to zero. The timer will start running again
automatically immediately.
Save timer
(chronometer) (
Saves the current value of the running timer at the trigger instant.
Sets the digital output, e.g. to the synchronous triggers of the
second oscilloscope channel of a KL3362. This function must be
released with bit 2 of the control byte 1 (CB1.2)
Start recording (
Starts the recording
Enable trigger unit 2
(
)
If the output of the And gate in trigger unit 1 is connected with the
function
Enable trigger 2
, the trigger signal is transferred to trigger
unit 2, which can be accessed via the
Unit 2
button in the
Selection
field for parameterization.
(KL3362 only)
Enable trigger unit 3
(
)
If the output of the And gate in trigger unit 2 is connected with the
function
Enable trigger 3
, the trigger signal is transferred to trigger
unit 3, which can be accessed via the
Unit 3
button in the
Selection
field for parameterization.
(KL3362 only)
Enable trigger unit 4
(
)
If the output of the And gate in trigger unit 3 is connected with the
function
Enable trigger 4
, the trigger signal is transferred to trigger
unit 4, which can be accessed via the
Unit 4
button in the
Selection
field for parameterization.
Содержание KL3361
Страница 1: ...Documentation KL3361 and KL3362 Oscilloscope Terminal 2 2 0 2019 10 17 Version Date...
Страница 2: ......