Access from the user program
KL2521
34
Version: 2.1
•
R39: Base frequency 2 (high word)
This register contains the high word of the base frequency 2.
The base frequency 2 is used if
◦ the ramp function is deactivated and
◦ the Frequency_Selection bit (Control.0) is 1.
•
R40: Ramp time constant (rising)
The ramp gradient for starting can be set in register 40 with a accuracy of 10 or 1000 Hz/s (
•
R41: Ramp time constant (falling)
The ramp gradient for stopping can be set with an accuracy of 10 or 1000 Hz / s (
)
using register 41.
•
R42: Frequency factor (direct input, digit x 10 mHz)
This register contains the frequency factor. If the frequency is entered directly (
= 1), the
process data are multiplied by the frequency factor (see
).
•
R43: Run-out frequency (travel distance control)
This register contains the run-out frequency (