Electrical installation
84
───
Version: 2.2
XTS
8.1
Connection technology
Beckhoff delivers supply modules with integrated and pre-assem-
bled power cables and EtherCAT cables. Mating connectors are not
included in the scope of supply. The cable end of the power supply
is pre-assembled with ferrules. The EtherCAT cable is available with
an RJ45 connector, connection TSB568A.
8.1.1
Cables
Beckhoff cables have been tested with regard to the materials,
shielding and connection method used. They ensure proper func-
tioning and compliance with statutory regulations such as EMC and
UL. The use of other cables may lead to unexpected interference
and invalidate the warranty.
For proper application and assembly we recommend:
• Wiring in accordance with applicable regulations and standards
• Use the pre-assembled and shielded Beckhoff cables for power
and EtherCAT connections
Laying
The following cables are integrated in the supply modules:
• 5 m orange power cable:
Lapp cable 3 x 2.5 mm
2
+ 2 x 0.75 mm
2
• 5 m green EtherCAT cable:
ZK1091-9191-050
Lay the cables so that they are protected against external damage.
Make sure that the cables lie in a position where they are protected
against moving machine parts and their acceleration forces. Beck-
hoff recommends "fixed installation", because the cables are not
suitable for drag chains.
Note the specified bending radii with different laying for the power
cables and EtherCAT cables in the table:
Bending radius
Laying
Power cable
EtherCAT cable
Fix-laid cables
69.6 mm, 6 x external
diameter
52.5 mm, 5 x external
diameter
Occasionally moved
cables
174 mm, 15 x exter-
nal diameter
78.75 mm, 7.5 x ex-
ternal diameter
Содержание eXtended Transport System
Страница 1: ...XTS eXtended Trans port System Operating Instructions EN 4 20 2020 Version 2 2 ...
Страница 2: ......
Страница 30: ...Product overview 30 Version 2 2 XTS 3 6 3O shape 3 6 3 3 6 4Z shape 3 6 4 ...
Страница 39: ...Technical data Version 2 2 39 XTS AT2000 0233 Motor straight 233 mm All figures in millimeters ...
Страница 40: ...Technical data 40 Version 2 2 XTS AT2002 0249 Motor straight 249 mm with plug All figures in millimeters ...
Страница 41: ...Technical data Version 2 2 41 XTS AT2002 0250 Motor straight 250 mm with plug All figures in millimeters ...
Страница 45: ...Technical data Version 2 2 45 XTS AT2026 0250 Motor 22 5 curved with power supply All figures in millimeters ...