Fault correction
Version: 2.2
───
101
XTS
The following tables describe a selection of errors that are displayed
either as "warning" or "error" messages. Depending on the applica-
tion, other causes may be responsible for the malfunction.
12.1
Motor modules
Changes from firmware version 15
ID
Up to firmware version 14
From firmware version 15
0x4101
Terminal-Overtemperature
Module overtemperature
0x8109
New from firmware version 15
0x810A
0x8403
0x840C
Omitted after firmware version 14
0x840B
Peak module overall current
threshold exceeded
Peak overall current threshold ex-
ceeded
12.1.1
Warning
12.1.1
ID
Message
Error
Number of the cause
0x4101
Module overtemperature
Motor module temperature exceeds
65 °C, see: COE 9000:19…9000:1C
1
0x4103
Undervoltage control voltage
24 V control voltage lower than
20.4 V
2
3
0x4411
Undervoltage DC-Link
48 V power supply is lower than 20 V
although the movers are not yet en-
abled
2
3
4
0x4412
Overvoltage DC-Link
48 V power supply is higher than 56 V
although the movers are not yet en-
abled
2
5
0x4414
I2T Motor overload
I2T utilization rate of the motor mod-
ule at over 80 %
6
Содержание eXtended Transport System
Страница 1: ...XTS eXtended Trans port System Operating Instructions EN 4 20 2020 Version 2 2 ...
Страница 2: ......
Страница 30: ...Product overview 30 Version 2 2 XTS 3 6 3O shape 3 6 3 3 6 4Z shape 3 6 4 ...
Страница 39: ...Technical data Version 2 2 39 XTS AT2000 0233 Motor straight 233 mm All figures in millimeters ...
Страница 40: ...Technical data 40 Version 2 2 XTS AT2002 0249 Motor straight 249 mm with plug All figures in millimeters ...
Страница 41: ...Technical data Version 2 2 41 XTS AT2002 0250 Motor straight 250 mm with plug All figures in millimeters ...
Страница 45: ...Technical data Version 2 2 45 XTS AT2026 0250 Motor 22 5 curved with power supply All figures in millimeters ...