Commissioning and configuration
EPP9022-0060
29
Version: 1.3
5.2
Measured values
5.2.1
Representation
• All measured voltage values are represented in mV / LSB in the factory setting.
They can optionally also be represented in µV / LSB.
• All measured current values are represented in mA / LSB in the factory setting.
They can optionally also be represented in µA / LSB.
The type of representation has no effect on the resolution of the measured values.
You can set the representation of the measured values individually for each measured value:
Input channel
CoE parameters for setting the representation
for the measured voltage value for the measured current value
1
Control voltage U
S
"
2
Peripheral voltage U
P