Commissioning and configuration
EPI4xxx, ERI4xxx
43
Version: 1.6
5.4
EPIxxxx, ERIxxxx - Setting of the IO-Link device
parameters
This chapter explains how to read out and set the IO-Link device parameters.
The number and type of the objects shown on the “Parameters” tab vary according to the type of sensor.
The default settings as stored in the IODD can initially be seen.
To open the “Parameter”
tab
1. Click the IO-Link master in the TwinCAT tree structure.
2. Click the “IO-Link” tab.
3. Select the port to which the IO-Link device is connected,
4. Double-click or by right-click to the port and select “Parameter”.
ð
The “Parameter”
tab is opened.
The device parameters are listed in the tab. The buttons
,
are located at the top of the tab. The “Read”
,
“Write”
and
“Store” buttons are used to read out the parameters stored in the IO-Link device, load them and store them
in the parameter server of the master.
Different user roles can be selected from the drop-down menu. The default user role is “Specialist”. The
parameters are displayed in different representations and scopes.
Restarting the IO link device or restoring of the application parameters is possible via the parameter
.
Application specific information can be specified in parameter (0x0018)