Commissioning/Configuration
EP3204 and EP3314
62
Version: 2.2
Index F000: Modular device profile
Index (hex) Name
Meaning
Data type
Flags
Default
F000:0
Modular device profile Maximum subindex
UINT8
RO
0x02 (2
dec
)
F000:01
Module index dis-
tance
Index spacing for the objects of the individual channels
UINT16
RO
0x0010 (16
dec
)
F000:02
Maximum number of
modules
Number of channels
UINT16
RO
0x0004 (4
dec
)
Index F008: Code word
Index (hex) Name
Meaning
Data type
Flags
Default
F008:0
Code word
reserved
UINT32
RW
0x00000000
(0
dec
)
Index F010: Module list
Index (hex) Name
Meaning
Data type
Flags
Default
F010:0
Module list
Maximum subindex
UINT8
RW
0x04 (4
dec
)
F010:01
SubIndex 001
UINT32
RW
0x00000140
(320
dec
)
F010:02
SubIndex 002
UINT32
RW
0x00000140
(320
dec
)
F010:03
SubIndex 003
UINT32
RW
0x00000140
(320
dec
)
F010:04
SubIndex 004
UINT32
RW
0x00000140
(320
dec
)
Index F080: Channel Enable
Index (hex) Name
Meaning
Data type
Flags
Default
F080:0
Channel Enable
Maximum subindex
UINT8
RO
0x04 (4
dec
)
F080:01
SubIndex 001
0
Channel 1 disabled
(from hardware version 01
deactivated channels are not
measured, and the green
LED R for these channels
goes out)
BOOLEAN
RW
0x01 (1
dec
)
1
Channel 1 enabled
F080:02
SubIndex 002
0
Channel 2 disabled
BOOLEAN
RW
0x01 (1
dec
)
1
Channel 2 enabled
F080:03
SubIndex 003
0
Channel 3 disabled
BOOLEAN
RW
0x01 (1
dec
)
1
Channel 3 enabled
F080:04
SubIndex 004
0
Channel 4 disabled
BOOLEAN
RW
0x01 (1
dec
)
1
Channel 5 enabled
Содержание EP3204