Operation
EP1918
38
Version: 1.1.0
4.5.2
Status LEDs
Fig. 27: EP1918-0002 Status LED
LED
Display
Meaning
1
on
Input 1 is connected and logical 1
off
Input 1 is not connected and logical 0
2
on
Input 2 is connected and logical 1
off
Input 2 is not connected and logical 0
3
on
Input 3 is connected and logical 1
off
Input 3 is not connected and logical 0
4
on
Input 4 is connected and logical 1
off
Input 4 is not connected and logical 0
5
on
Input 5 is connected and logical 1
off
Input 5 is not connected and logical 0
6
on
Input 6 is connected and logical 1
off
Input 6 is not connected and logical 0
7
on
Input 7 is connected and logical 1
off
Input 7 is not connected and logical 0
8
on
Input 8 is connected and logical 1
off
Input 8 is not connected and logical 0
Us
on
Control voltage Us is available
off
Control voltage Us is not available
Up
on
Control voltage Up is available
off
Control voltage Up is not available