Object description and parameterization
EL72x1-901x
212
Version: 1.9
7.2.1
Configuration data
Index 2002 Amplifier Settings
Index (hex) Name
Meaning
Data type Flags Default
2002:0
Amplifier Settings
Maximum subindex
UINT8
RO
0x49 (73
dec
)
2002:11
Device type
1: Servo drive (cannot be changed)
UINT32
RW
0x00000001 (1
dec
)
2002:12*
Current loop integral
time
Integral component of current controller
Unit:
0.1 ms
This value is affected by automatic scanning. (see
tomatic scanning of the electronic type plates [
UINT16
RW
0x000A (10
dec
)
2002:13*
Current loop proportional
gain
Proportional component of current controller
Unit:
0.1 V/A
This value is affected by automatic scanning. (see
tomatic scanning of the electronic type plates [
UINT16
RW
0x0064 (100
dec
)
2002:14
Velocity loop integral
time
Integral component of velocity controller
Unit:
0.1 ms
UINT32
RW
0x00000032
(50
dec
)
2002:15
Velocity loop propor-
tional gain
Proportional component of velocity controller
Unit:
mA / (rad/s)
UINT32
RW
0x00000096
(150
dec
)
2002:17
Position loop propor-
tional gain
Proportional component position controller
Unit:
(rad/s) / rad
UINT32
RW
0x0000000A
(10
dec
)
2002:19
Nominal DC link voltage Nominal DC link voltage
Unit
: mV
UINT32
RW
0x0000BB80
(48000
dec
)
2002:1A
Min DC link voltage
Minimum DC link voltage
Unit
: mV
UINT32
RW
0x00001A90
(6800
dec
)
2002:1B
Max DC link voltage
Maximum DC link voltage
Unit
: mV
UINT32
RW
0x0000EA60
(60000
dec
)
2002:29
Amplifier I2T warn level
I²T model warning threshold
Unit
: %
UINT8
RW
0x50 (80
dec
)
2002:2A
Amplifier I2T error level
I²T model error threshold
Unit
: %
UINT8
RW
0x69 (105
dec
)
2002:2B
Amplifier temperature
warn level
Overtemperature warning threshold
Unit
: 0.1 °C
UINT16
RW
0x0320 (800
dec
)
2002:2C
Amplifier temperature er-
ror level
Overtemperature error threshold
Unit
: 0.1 °C
UINT16
RW
0x03E8 (1000
dec
)
2002:31
Velocity limitation
Velocity limitation
Unit
: rpm
UINT32
RW
0x00040000
(262144
dec
)
2002:32
Short circuit brake dura-
tion max
Max. duration of armature short circuit brake
Unit
: ms
UINT16
RW
0x03E8 (1000
dec
)
2002:33
Stand still window
Standstill window
Unit
: rpm
UINT16
RW
0x0000 (0
dec
)
2002:41
Low-pass filter frequency Low-pass filter frequency
Unit
: Hz
The following values can be set:
0 Hz = off
160 Hz
320 Hz
UINT16
RW
0x0140 (320
dec
)
2002:49
Halt ramp deceleration
Halt ramp deceleration
Unit
: 0.1 rad / s²
UINT32
RW
0x0000F570
(62832
dec
)
Содержание EL72 1-901 Series
Страница 1: ...Documentation EL72x1 901x Servo Motor Terminals with OCT and STO 50 V DC 1 9 2020 02 18 Version Date...
Страница 2: ......
Страница 6: ...Table of contents EL72x1 901x 6 Version 1 9...
Страница 20: ...Product overview EL72x1 901x 20 Version 1 9 2 3 Technical data...
Страница 49: ...Installation EL72x1 901x 49 Version 1 9 Fig 36 Shield busbar Fig 37 Shield busbar clamp...
Страница 86: ...Commissioning EL72x1 901x 86 Version 1 9 Fig 88 Incorrect driver settings for the Ethernet port...
Страница 140: ...Commissioning EL72x1 901x 140 Version 1 9 0hex 80hex Fault reset 6hex Shutdown 7hex Switch on Fhex Enable operation...
Страница 141: ...Commissioning EL72x1 901x 141 Version 1 9 Fig 176 DS402 State Machine...
Страница 150: ...Commissioning EL72x1 901x 150 Version 1 9 Fig 184 Touch Probe inputs...
Страница 172: ...Commissioning EL72x1 901x 172 Version 1 9 Fig 207 Process Data tab SM2 EL72x1 0010 default...
Страница 256: ...Appendix EL72x1 901x 256 Version 1 9 9 5 Certificates Fig 233 EL72x1 9014_Certificate...