Commissioning
EL33xx-00x0
156
Version: 4.2
5.10.1
Restore object
Index 1011 Restore default parameters
Index (hex) Name
Meaning
Data type
Flags
Default
1011:0
Restore default parameters
UINT8
RO
0x01 (1
dec
)
1011:01
SubIndex 001
If this object is set to "
0x64616F6C"
in the set value
dialog, all backup objects are reset to their delivery
state.
UINT32
RW
0x00000000 (0
dec
)