background image

Manual | EN

CX2100-0014

Power supply unit for CX20x0 and CX20x2

6/30/2020 | Version: 1.2

Содержание CX2100-0014

Страница 1: ...Manual EN CX2100 0014 Power supply unit for CX20x0 and CX20x2 6 30 2020 Version 1 2...

Страница 2: ......

Страница 3: ...sible installation positions 16 5 1 4 Attaching on mounting rail 18 5 1 5 Installing passive EtherCAT Terminals 19 5 2 Power supply 20 5 2 1 Connect Embedded PC 20 5 2 2 Observe the UL requirements 22...

Страница 4: ...Table of contents CX2100 0014 4 Version 1 2...

Страница 5: ...products that have already been supplied may be made on the basis of the data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT EtherCAT G EtherCAT G10 EtherCAT P Sa...

Страница 6: ...with medium risk of death or serious injury CAUTION Slight risk of injury There is a low risk hazard that can result in minor injury Warnings relating to damage to property or the environment NOTE Da...

Страница 7: ...entation can be viewed at and downloaded from the Beckhoff website http www beckhoff de Document name CX20x0 multi core Retaining the documentation This documentation is part of the power supply unit...

Страница 8: ...us Terminals to receive digital and analog signals from sensors and output them to actuators or forward them to higher level controllers The power supply units CX2100 0014 are designed for a working e...

Страница 9: ...the IT security precautions according to IEC 62443 in order to limit access to and control of devices and networks Working with the software Use up to date security software The safe function of the...

Страница 10: ...ondensation has occurred wait at least 12 hours before switching on the power supply unit Despite the robust design of the unit the components are sensitive to strong vibrations and impacts Protect th...

Страница 11: ...automatically recognizes the respective bus system K bus or E bus Further power supply units A total of four different power supply units are available for the Embedded PCs of the CX2000 series CX2100...

Страница 12: ...4 For navigation in menus 6 Diagnostic LEDs 41 power supply terminal Diagnosis of the power supply for the Embedded PC and the Terminal Bus Status of the E bus and K bus communication 7 Spring loaded...

Страница 13: ...Table 4 Legend for the name plate No Description 1 UL approval with prescribed information on power supply fuse temperature and cable cross sections 2 Information on the power supply unit 3 Informatio...

Страница 14: ...upply unit into the high pole connection on the right on the basic CPU module 2 Check whether the power supply unit is flush with the Embedded PC In the next step you can install the bar clips 5 1 2 I...

Страница 15: ...2 3 Check that the bar clips are flush The bar clips have been installed successfully if they don t protrude and are level with the cooling fins of your modules Once all modules are latched the device...

Страница 16: ...that excess heat is dissipated from the control cabinet The power supply unit CX2100 0014 and the Embedded PC are mounted horizontally on the mounting rail as standard A vertical or horizontal mountin...

Страница 17: ...prevent it slipping off the DIN rail Install a bracket below the Embedded PC for this purpose Horizontal mounting position Maintain the ambient temperatures The minimum distance of at least 30 mm abo...

Страница 18: ...N EN 60715 Secure the Embedded PC on the mounting rail as follows 1 Unlock the latches at the top and bottom 2 Place the Embedded PC at the front of the mounting rail Slightly press the Embedded PC on...

Страница 19: ...5 can be detected in TwinCAT In the tree structure the EtherCAT Terminal is displayed without process image and the value in column E bus mA does not change compared to the preceding EtherCAT Terminal...

Страница 20: ...06 PELV Protective Extra Low Voltage The PE and 0 V conductors of the voltage source for a basic CPU module must be on the same potential connected in the control cabinet Standard EN 60204 1 2006 sect...

Страница 21: ...holding the wire safely and permanently The voltage source has been connected to the power supply unit successfully when the two upper power supply terminal LEDs light up in green The left LED Us ind...

Страница 22: ...which special UL requirements have to be met UL requirements The Embedded PCs must not be connected to unlimited voltage sources Embedded PCs may only be supplied from a 24 V DC voltage source The vol...

Страница 23: ...spond to ASCII ISO 8859 1 from 0x20 to 0x7E Hex Character Hex Character Hex Character 0x20 0x40 0x60 0x21 0x41 A 0x61 a 0x22 0x42 B 0x62 b 0x23 0x43 C 0x63 c 0x24 0x44 D 0x64 d 0x25 0x45 E 0x65 e 0x26...

Страница 24: ...function blocks Their names are FB_CXSetTextDisplayUSB FB and FB_CXGetTextDisplayUSB FB Parameters are written with FB_CXSetTextDisplayUSB FB and the status values are read from the function block wi...

Страница 25: ...Build 4015 With older versions an update is required for the use of the function blocks Illustration of the display with the System Manager There are six tabs in the System Manager These are briefly...

Страница 26: ...the EtherCAT device Type EtherCAT device type Comment Here you can add a comment e g regarding the system Disabled Here you can deactivate the EtherCAT device Tab ESB Device The settings for the excha...

Страница 27: ...of the devices on the BUS Device Handle Pointer to the device driver Data Exchange Cycle in which the communication takes place ADS Port address for ADS access 7100 for the TwinCAT function block Tab...

Страница 28: ...Configuration CX2100 0014 28 Version 1 2 Tab CoE Online...

Страница 29: ...ble and unchangeable parameters of a device Such a parameter encompasses at least the following characteristics Index number for the unambiguous identification of all parameters The index number is di...

Страница 30: ...nges in the Slave CoE that are important for the application oriented EtherCAT fieldbus user are x1000 This is where fixed identity information for the device is stored including name manufacturer ser...

Страница 31: ...ocal CoE values permanently the Startup list must be used The startup list is used for these cases the values here which are entered by the user are transmitted to the respective slave upon each Ether...

Страница 32: ...rCAT communication is displayed here It can also be switched to a different state here This is done by selecting the desired state by a mouse click on the appropriate button The individual states are...

Страница 33: ...en Pre Op and Safe Op the EtherCAT slave checks whether the sync manager channels for process data communication and if required the distributed clocks settings are correct Before it acknowledges the...

Страница 34: ...d in the PLC The values of the button can be assessed as a numerical value via a TwinCAT function A combination of the buttons can also be assessed via the value The register can be accessed from with...

Страница 35: ...n can be initiated e g CASE Taster OF 4 ACTION UP 8 ACTION DOWN 16 ACTION LEFT 32 ACTION RIGHT 64 ACTION SELECT END_CASE In this case ACTION is a newly defined ENUM type It is also possible for the de...

Страница 36: ...tTextDisplayUSB bExecuteWrite BOOL eModeWrite E_CX2100_DisplayModesWr bCursorOnReq BOOL bCursorOffReq BOOL bBlinkCursorOnReq BOOL bBlinkCursorOffReq BOOL bBacklightOnReq BOOL bBacklightOffReq BOOL bCl...

Страница 37: ...ghtReq FALSE eCX2100_ReadLine1 sLine1 fbGetDisplayText sLine1 bReadLine1Req FALSE eCX2100_ReadLine2 sLine2 fbGetDisplayText sLine2 bReadLine2Req FALSE eCX2100_ReadLines sLine1 fbGetDisplayText sLine1...

Страница 38: ...Write TRUE bReadCursorInfoReq TRUE ELSIF bSetCursorPosYReq THEN eModeWrite eCX2100_CursorPosY bExecuteWrite TRUE bReadCursorInfoReq TRUE ELSIF bSetCursorPosXYReq THEN eModeWrite eCX2100_CursorPosXY bE...

Страница 39: ...2 USINT END_VAR The error can then be determined in the PLC program as follows this is pseudo code which is not directly executable in this form IF k_bus_state 0 THEN auf dem K Bus ist ein Fehler aufg...

Страница 40: ...cs CX2100 0014 40 Version 1 2 k_bus_request TRUE R cksetzen des Busses wenn Fehler beseitigt dann startet der Klemmbus wieder In order for the controller and the registers to co operate they must be l...

Страница 41: ...he fieldbus system is also running K BUS ERR Diagnostic K bus The red LED flashes to indicate an error The red LED blinks with two different frequencies The frequency and number of the flashes can be...

Страница 42: ...whether the Bus End Terminal 9010 is connected n Break behind Bus Terminal n Check whether Bus Terminal n 1 after the power supply unit is connected correctly replace if necessary 5 pulses n K bus err...

Страница 43: ...faster than 100 ms We recommend a task time of less than 50 ms The K bus update time typically lies between one and five ms Table 10 Description of the State variable values Bit Description Bit 0 K b...

Страница 44: ...s lit in E bus mode The L A LED flashes during data transfer Display LED Meaning Us 24 V Power supply for basic CPU module The LED lights green if the power supply is correct Up 24 V Power supply for...

Страница 45: ...f the power supply Only then can you remove all the cables Also remove all cables from the first terminal after the power supply terminal Requirements Exit the software and shut down the Embedded PC S...

Страница 46: ...or removed quite easily This section describes how to remove devices from the CX2000 Embedded PC series Requirements All cables were removed from the Embedded PC Dismantle the Embedded PC as follows...

Страница 47: ...iver and remove the bar clips Once the bar clips have been removed successfully the modules can be separated from each other Disposal The device must be fully dismantled in order to dispose of it Elec...

Страница 48: ...13 Technical data I O terminals Technical data CX2100 0014 I O connection K bus or E bus automatic recognition Power supply for I O terminals max 2 A Power contacts current loading max 10 A Process da...

Страница 49: ...of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and c...

Страница 50: ...mponents there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Support of...

Страница 51: ...issible mounting positions 16 Table 6 Legend for the connection example 20 Table 7 Required wire cross sections and strip lengths 21 Table 8 K bus ERR LED fault indication sequence through the LED 41...

Страница 52: ...ing position 16 Fig 4 CX2040 Embedded PC vertical mounting position 17 Fig 5 CX2040 Embedded PC horizontal mounting position 17 Fig 6 Identifying a passive EtherCAT Terminal in TwinCAT 19 Fig 7 Passiv...

Страница 53: ......

Страница 54: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com cx2100 0014...

Отзывы: