Beckhoff CP63 Series Скачать руководство пользователя страница 6

General instructions 

 

 

 
 

Operator's obligation to exercise diligence 

 

The operator must ensure that 

• 

the Industrial PC is only used for its intended use (see also 

Product Description

 chapter). 

• 

the Industrial PC is in a sound condition and in working order 
during operation. 

• 

the operation manual is in good condition and complete, and 
always available for reference at the location of the Industrial PC. 

• 

the Industrial PC is operated, maintained and repaired only by 
sufficiently qualified and authorised personnel. 

• 

the personnel is instructed regularly about relevant occupational 
safety and environmental protection aspects, and is familiar with 
the operating manual and in particular the safety notes contained 
herein. 

• 

none of the safety and warning notes attached to the Industrial PC 
are removed, and that all notes remain legible. 

 

National regulations  
depending on the machine 
type 

Depending on the type of machine and plant in which the Industrial PC is 
being used, there will be national regulations for the control of such 
machines and plant that the operator must observe. These regulations 
cover, amongst other things, the intervals between inspections of the 
controller. 
 
The operator must initiate such inspections in good time. 
 

 

Warning

 

 

Only trained persons may open the Industrial PC housing! 

The operator is responsible for ensuring that only trained electrical staff 
opens the housing of the Industrial PC. 
 

 

 

Procedure in the event of a 
fault 

In the event of a fault in the Industrial PC, appropriate measures can be 
determined with the aid of the list in the 

Fault correction

 section. 

 

 

Operator requirements  

Read the operating 
instructions 

Every user of the Industrial PC must have read these operating 
instructions. 
 

Software knowledge 

Every user must be familiar with any of the functions of the software 
installed on the PC that he can reach. 
 

 

4

 

CP63XX 

Содержание CP63 Series

Страница 1: ...Installation and Operating instructions for Built in Panel PC CP63xx Version 1 3 Date 2006 01 11...

Страница 2: ......

Страница 3: ...npacking 8 Installation of the PC in the control cabinet 9 Earthing measures 9 Power supply 10 Connecting devices 11 Connecting cables 11 Verifying the voltage and connecting 11 Operating Instructions...

Страница 4: ...he meaning of 443 BGB of the German Civil Code or a statement about the contractually expected fitness for a particular purpose in the meaning of 434 par 1 sentence 1 BGB In the event that it contains...

Страница 5: ...equipment must first be switched off after which the Industrial PC can be uncoupled from the plant Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that have been...

Страница 6: ...National regulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of such machin...

Страница 7: ...plant engineering applications Structure Opening the housing To open the PC housing release the screw 1 by one turn using a screwdriver The plastic cap 2 can be then be pulled forward thereby releasi...

Страница 8: ...asic configuration The computer chassis can now be removed from the housing The power supply 1 and the hard disk 2 are located in the lower part of the chassis The slot motherboard 3 is located in the...

Страница 9: ...o be used while a PC keyboard can be connected to the lower PS 2 connector 7 VGA connection VGA A 15 pin SUB D socket connector 5 allows a VGA monitor to be connected free slot free slot A free slot 7...

Страница 10: ...ns in temperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur...

Страница 11: ...e unit is in its mounting position the ventilation openings must not be obstructed Warning Extreme environmental conditions should be avoided as far as possible Protect the rear of your PC from dust h...

Страница 12: ...ower supply unit Output voltages from the 24 V power supply unit Current loading maximum 5 V 8 A 5 V 0 5 A 12 V 4 A 12 V 0 5 A 3 3 V 4 A 5 V VSB 0 5 A Pin assignment and fuse protection Pin assignment...

Страница 13: ...ces that are to be connected Disconnect all the devices that are to be connected from the power supply Connect all the cables between the Industrial PC and to the devices that are to be connected Conn...

Страница 14: ...software is writing a file to the hard disk the file will be destroyed Control software typically writes something to the hard disk every few seconds so that the probability of causing damage by swit...

Страница 15: ...as to be replaced according to the rules of the board manufactorer Danger Danger of Explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufactur...

Страница 16: ...incorrect Other cause Remove floppy disk or CD and press any key Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault...

Страница 17: ...C Beckhoff Support Support offers you comprehensive technical assistance helping you no only with the application of individual Beckhoff products but also with other wide ranging services world wide s...

Страница 18: ...re to be observed during transport and storage as in operation The shock resistance during transport can be improved by means of suitably packing the Industrial PC The ambient temperature during stora...

Отзывы: