background image

 

Foreword 

 

Foreword 

 

Notes on the Documentation 

 

This description is only intended for the use of trained specialists in control 
and automation engineering who are familiar with the applicable national 
standards. It is essential that the following notes and explanations are 
followed when installing and commissioning these components. 
The responsible staff must ensure that the application or use of the 
products described satisfy all the requirements for safety, including all the 
relevant laws, regulations, guidelines and standards. 

 

Liability Conditions 

 

The documentation has been prepared with care. The products described 
are, however, constantly under development. For that reason the 
documentation is not in every case checked for consistency with 
performance data, standards or other characteristics. In the event that it 
contains technical or editorial errors, we retain the right to make alterations 
at any time and without warning. No claims for the modification of products 
that have already been supplied may be made on the basis of the data, 
diagrams and descriptions in this documentation. 

 

Trademarks 

 Beckhoff

®

, TwinCAT

®

, EtherCAT

®

, Safety over EtherCAT

®

, TwinSAFE

®

 

and XFC

®

 are registered trademarks of and licensed by Beckhoff 

Automation GmbH. 
Other designations used in this publication may be trademarks whose use 
by third parties for their own purposes could violate the rights of the 
owners. 

 

Patent Pending 

 

The EtherCAT Technology is covered, including but not limited to the 
following patent applications and patents: 
EP1590927, EP1789857, DE102004044764, DE102007017835 
with corresponding applications or registrations in various other countries. 
The TwinCAT Technology is covered, including but not limited to the 
following patent applications and patents: 
EP0851348, US6167425 with corresponding applications or registrations in 
various other countries. 

 

Copyright 

 

© Beckhoff Automation GmbH. 
The reproduction, distribution and utilization of this document as well as the 
communication of its contents to others without express authorization are 
prohibited. Offenders will be held liable for the payment of damages. All 
rights reserved in the event of the grant of a patent, utility model or design. 

 

State at Delivery 

 

All the components are supplied in particular hardware and software 
configurations appropriate for the application. Modifications to hardware or 
software configurations other than those described in the documentation 
are not permitted, and nullify the liability of Beckhoff Automation GmbH. 

 

Delivery conditions 

 

In addition, the general delivery conditions of the company Beckhoff 
Automation GmbH apply. 

CP62xx 

Содержание CP62 Series

Страница 1: ...Installation and Operating instructions for Economy built in Panel PC CP62xx Version 2 7 Date 2012 04 02...

Страница 2: ...t and Unpacking 9 Transport 9 Unpacking 9 Installation of the PC in the control cabinet 10 Installation in a control cabinet wall 10 Earthing measures 10 Mounting of the Panel PC 11 Power Supply Conne...

Страница 3: ...e PC 22 Help files 22 Troubleshooting 23 Fault correction 23 Beckhoff Support Service 24 Beckhoff branches and partner companies 24 Beckhoff Headquarters 24 Beckhoff Support 24 Beckhoff Service 24 App...

Страница 4: ...ed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners Patent Pending The...

Страница 5: ...als Risk of injury WARNING If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safety...

Страница 6: ...en switched off must be secured against being switched on again The Industrial PC s power supply unit must be supplied with 24VDC Do not open the power supply unit while voltage is applied CAUTION The...

Страница 7: ...ser is familiar with all the functions of the software installed on the Industrial PC to which he has access National regulations depending on the machine type Depending on the type of machine and pla...

Страница 8: ...RS232 which is brought to a 9 pin SUB D plug connector COM2 Touchpad or additional interface optional The serial interface COM2 is connected to the touchpad optional When the IPC is delivered without...

Страница 9: ...cess to the drives and the battery Access to hard disk CF Card and battery After solving the knurled screw the cap can be removed and allows access to hard disk battery and CF Card Status LEDs Descrip...

Страница 10: ...temperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a del...

Страница 11: ...allation height it should be optimally visible for the user at all times The PC should not be exposed to direct sunlight When the unit is in its mounting position the ventilation openings must not be...

Страница 12: ...PC cutout dimensions Mounting of the Panel PC Clamping levers Release clamping levers Insert the PC into the cutout Release the clamping levers with a No 2 5 Allen key Folding them out Turn the clamp...

Страница 13: ...ltage In this case the PC shuts down via the battery However over time this reduces the service life of the battery The new Beckhoff power supply technology approach addresses this problem and now off...

Страница 14: ...ched off in order to avoid total discharge of the battery For a detailed functional description please refer to section Connecting Power Supply Pin assignment of the connector The power supply and the...

Страница 15: ...s specified for 16 A and can lift conductive cross sections until 1 5 mm2 Fitting the connector to the cable So the connector is fitted to the cable 1 Strip insulation from the cable ends Length of st...

Страница 16: ...inverted i e the PC shuts down if the 24 V connection is live If the PC_ON input is NOT connected by the user the PC can be booted in the familiar way by connecting the supply voltage and shut down v...

Страница 17: ...g diagram the circuit of PC_ON and Power Status is symbolical Wiring diagram external switch and power supply Connection of the Battery Pack and UPS Output Note Connection of the Battery Pack and UPS...

Страница 18: ...to be connected Disconnect all the devices that are to be connected from the power supply Connect all the cables between the Industrial PC and to the devices that are to be connected Connect all data...

Страница 19: ...tention When you have shut down the Industrial PC you have to switch off power supply for at least 10 seconds before rebooting the system After resetting power supply the PC will start booting automat...

Страница 20: ...f the cursor to be overwritten The overwrite mode is cancelled by pressing the key again Print Print Screen prints a hard copy of a text screen on the printer Pause The Pause key stops the computer un...

Страница 21: ...is displayed at the bottom edge of the display Einschub Streifen Einschub Streifen Einschub Streifen Einschub Streifen The function of the special keys above the display is also determined by the soft...

Страница 22: ...uild in Panel PC Note For technical support contact Beckhoff Service Replacing the battery on the motherboard A used battery on the motherboard has to be replaced See also chapter Access to the drives...

Страница 23: ...the driver CD provided Installation on the PC Installation To install the UPS driver software execute file Beckhoff_UPS_vx xx xx exe from the subdirectory of UPS from the CD provided on the Industrial...

Страница 24: ...s Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the plant outside the Industrial PC Call the m...

Страница 25: ...rstra e 5 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Beckhoff offers you comprehensive technical assistance helping you not only with the...

Страница 26: ...9 33 Dimensions CP621x a b t A B C D CP6211 12 Display 372 2 342 2 58 358 2 328 2 67 32 5 CP6212 15 Display 430 4 403 59 416 4 389 86 5 33 CP6213 19 Display 508 4 463 67 494 4 449 116 2 33 Dimensions...

Страница 27: ...sport and storage as in operation Suitable packaging of the Industrial PC can improve the resistance to impact during transport The ambient temperature during storage and transport must be between 20...

Отзывы: