Commissioning
CP22xx
29
Version: 2.0
4.3.3
Connecting cables and power supply
NOTE
Incorrect connection procedure
Incorrect procedure when connecting the cables and the power supply can cause hardware damage.
• Follow the documented procedure for connecting the cables and the power supply.
• Always connect all cables first and only then switch on the power supply.
• Please read the documentation for the external devices prior to connecting them.
NOTE
Connection of incorrect battery packs
Connecting the wrong battery packs can cause damage to the Panel PC and the battery packs.
• Only connect the C9900-U330 Beckhoff battery pack to your Panel PC.
The connections are located at the rear of the Panel PC.
Connecting cables
Make sure that you first ground the PC (see chapter 4.3.2
data transmission lines.
Connecting the power supply
Cables with a maximum cable cross-section of 1.5 mm
2
can be used for connecting the power supply. For
long supply lines, use 1.5 mm
2
cables to achieve a low voltage drop on the supply line. There should be at
least 22 V at the voltage connector of the Panel PC, so that the PC remains switched on during voltage
fluctuations.
Proceed as follows to connect the 24 V
DC
power supply unit:
1. Mount power supply cable.
2. Plug the voltage connector into the voltage socket on the Panel PC.
3. Screw the voltage connector to the voltage socket.
4. Connect the PC to your external 24 V power supply.
5. Switch on the 24 V power supply.
6. Measure the voltage on the power supply plug of the PC.
External battery pack
If you ordered your device with an integrated UPS, then you can connect an external battery pack and install
it on a DIN rail near to the PC. Use only Beckhoff battery packs for this:
Table 10: Order identifier battery pack
Order identifier
Version
C9900-U330
Battery pack for PCs with 24 V power supply unit and integrated UPS C9900-
P209 or C9900-U209, external for DIN rail mounting, 3.4 Ah, operating
temperature 0...50 °C, contains two closed lead-acid batteries VRLA-AGM
You can use the UPS output of the power supply unit and connect a Beckhoff Control Panel as a second
display. If the supply voltage fails and the Panel PC is only supplied by the battery pack, the Control Panel
remains in operation. Second display operators can use it to read the power failure notification, back up data,
and shut down the operating system.
PIN 4 and 5 of the battery pack are available for looping through a 24 V power supply. Accordingly, you can
connect a three-core sheathed cable with plus and minus of the supply voltage as well as protective earth to
the battery pack and then connect to the PC with a five-core sheathed cable. The method of connecting
different components can be taken from the wiring diagram in fig. 18.
Содержание CP22 Series
Страница 1: ...Manual EN CP22xx Panel PC 2022 7 26 Version 2 0...
Страница 2: ......
Страница 4: ...Table of contents CP22xx 4 Version 2 0...
Страница 10: ...Product overview CP22xx 10 Version 2 0 1 2 Fig 1 CP22xx_without and with push button extension...
Страница 27: ...Commissioning CP22xx 27 Version 2 0 Fig 16 CP22xx_disassembly the strain relief housing...
Страница 52: ......