Beckhoff C6930 Скачать руководство пользователя страница 1

Manual | EN

C6930

Industrial PC

6/29/2021 | Version: 2.0

Содержание C6930

Страница 1: ...Manual EN C6930 Industrial PC 6 29 2021 Version 2 0...

Страница 2: ......

Страница 3: ...19 4 2 Installation in the control cabinet 20 4 2 1 Dimensions 21 4 2 2 Installation in the control cabinet 23 4 3 Connecting the Industrial PC 25 4 3 1 Installing the supply cable 26 4 3 2 Grounding...

Страница 4: ...Table of contents C6930 4 Version 2 0 10 2 Approvals 48...

Страница 5: ...CAT EtherCAT G EtherCAT G10 EtherCAT P Safety over EtherCAT TwinSAFE XFC XTS and XPlanar are registered and licensed trademarks of Beckhoff Automation GmbH Other designations used in this publication...

Страница 6: ...th or serious injuries WARNING Disregarding the safety notice may lead to death or serious injuries CAUTION Disregarding the safety notice may lead to minor injuries Warning of damage to property NOTE...

Страница 7: ...ssipation please refer to the respective data sheet Ensure that only trained specialists with a control and automation technology background operate the Industrial PC Use by unauthorized persons can l...

Страница 8: ...diverse automation and visualization tasks wide range of IoT tasks with data preprocessing complicated HMI applications extensive axis controllers short cycle times high volume data handling The basic...

Страница 9: ...of PCIe modules or for leading out motherboard interfaces ex factory 5 Front flap Access to battery and storage media 6 Grounding screw Functional earthing of the Industrial PC 7 Fan cartridge tool le...

Страница 10: ...PIN 6 24 V of the socket If the Industrial PC is equipped with an integrated uninterruptible power supply UPS an external battery pack can additionally be connected to PIN 1 and PIN 2 X101 8 1 P S PC...

Страница 11: ...ble for cycle times 1 ms and for distributed clock applications with EtherCAT The Ethernet port i219 integrated in the chipset is usually suitable for real time Ethernet applications with cycle times...

Страница 12: ...s based on device generation Generation USB interfaces C6930 0050 2x USB 3 0 2x USB 2 0 C6930 0060 4x USB 3 0 C6930 0070 4x USB 3 1 1 2 3 4 4 3 2 1 5 6 7 8 9 5 6 7 8 9 1 2 3 4 4 3 2 1 5 6 7 8 9 5 6 7...

Страница 13: ...not connected 13 not connected 21 not connected 6 DDC Clock 14 5V Power 22 TDMS Clock Shield 7 DDC Data 15 Ground 5 V Analog H V Sync 23 TDMS Clock 8 Analog Vertical Sync 16 Hot Plug Detect 24 TDMA C...

Страница 14: ...d slots C6930 0050 C6930 0060 C6930 0070 C9900 E292 Additional DisplayPort interface fed out to a module cover max resolution 1920 x 1080 can be ordered only once per PC and not together with a second...

Страница 15: ...x1 plug in card slots on passive backplane integrated in the C6930 for the insertion of PCIe x1 plug in cards up to 190 mm in length C9900 B511 2 PCI plug in card slots on passive backplane integrate...

Страница 16: ...e inserted the plug in cards the card connections are located on the right on the top side of the PC see fig 9 Fig 9 C6930_Plug in card connections The additional plug in card slots change the dimensi...

Страница 17: ...s activity the fieldbus status The figure shows where the LEDs are located on the Industrial PC Fig 10 C6930 Status LEDs Table 11 Meaning of the Status LEDs LED Color flashing interval Meaning PWR Pow...

Страница 18: ...ast four digits indicate the device generation 2 Serial number BTN 3 Date of manufacture 4 Mainboard 5 CPU 6 Main memory 7 Mini PCI slot 8 PCIe module slots 9 Storage media 10 Storage media 11 Power s...

Страница 19: ...iate packaging of the Industrial PC in particular the original packaging can improve the vibration resistance during transport NOTE Hardware damage due to condensation Unfavorable weather conditions d...

Страница 20: ...ou can align the cable entry based on the application requirements Figure 12 shows the two available mounting plates the standard mounting plate 1 and the optional mounting plate 2 Mounting plate 1 in...

Страница 21: ...trates the dimensions of the Industrial PC with mounting plate 2 94 3 262 222 5 124 5 65 245 Fig 14 C6930_Dimensions with mounting plate 2 If you have chosen the ordering option for the device with ad...

Страница 22: ...ion 2 0 Figure 16 illustrates the dimensions of the Industrial PC with mounting plate 4 and the additional plug in card slots 222 5 262 159 2 163 2 137 90 245 Fig 16 C6930_Dimensions with mounting pla...

Страница 23: ...l cabinet using the mounting plates the control cabinet must be equipped with drill holes for the fastening screws corresponding to the dimensions of the PC see chapter 4 2 1 Dimensions 21 You need M4...

Страница 24: ...ing C6930 24 Version 2 0 2 Hang the PC on the screws at the marked places on the mounting plate see fig 17 3 Tighten the fastening screws You have successfully installed the Industrial PC in the contr...

Страница 25: ...evice To prepare the Industrial PC for operation it must be connected The first step is to ground the device Then you can connect the cables and the power supply An external power supply unit is requi...

Страница 26: ...in connection strip For the pin assignment of the connector see Chapter 3 2 1 Power supply 10 Assembly of the strain relief housing Now mount the strain relief housing on the already connected connect...

Страница 27: ...ective earth PE EMC NOTE Hardware damage due to electromagnetic interference Using the Industrial PC without functional earthing can lead to hardware damage due to electromagnetic in terference Only u...

Страница 28: ...drop on the supply line we recommend connecting the maximum possible cross section In case of larger distances between the power source and the PC take into account the voltage drop in relation to the...

Страница 29: ...am So that the Industrial PC still has a monitor output in case of a power failure a Control Panel can be connected to the UPS output of the power supply unit Even after a power failure there is a vol...

Страница 30: ...gnificantly shortens the life of the battery Avoid switching off the power supply before shutting down the operating system Use the Beckhoff concept see below to shut down the operating system in a ba...

Страница 31: ...The driver software comes with a detailed help function Call up the help files either directly from the configuration tab by clicking the Help button or start the file under Start Programs Beckhoff UP...

Страница 32: ...Beckhoff Device Manager to remotely configure the Industrial PC via a web browser More detailed information is available in the Beckhoff Device Manager manual Starting the Beckhoff Device Manager for...

Страница 33: ...passwords are an important prerequisite for a secure system Beckhoff supplies the device images with standard user names and standard passwords for the operating system It is imperative that you chang...

Страница 34: ...lectric shock Never disconnect the cables from the device during thunderstorms Before you remove the Industrial PC from the control cabinet you must follow the following steps 1 Shut down the operatin...

Страница 35: ...at they remain attached to the control cabinet 2 Lift the PC far enough so that the mounting screws slip into the keyholes see fig 22 3 Remove the PC from the control cabinet You have successfully dis...

Страница 36: ...rts such as fans and circuit boards must be disposed of in accordance with national electronic scrap regulations Stick insulating tape over the poles of the CR2032 battery on the motherboard and dispo...

Страница 37: ...onents and the replacement of other device components contribute to this Repair Only the manufacturer may repair the device If a repair should be necessary contact Beckhoff Service see Chapter 10 1 Se...

Страница 38: ...mmendation for replacement intervals years UPS battery pack 5 years 2 5 inch hard disk 5 years or after 20 000 operating hours at more than 40 C or after 30 000 operating hours at less than 40 C 3 5 i...

Страница 39: ...the device against ESD damage For example the following measures can be used Use conductive mats connected to the ground potential as underlays Dissipate possible charges from your own body by touchi...

Страница 40: ...ess to battery and storage media To get access to the battery and the storage media open the front flap see fig 23 Fig 23 C6930_tool less access to battery and storage media You now have access to the...

Страница 41: ...supply power to the clock integrated on the motherboard If the battery is depleted or missing the date and time are displayed incorrectly Table 15 Technical data of the battery Battery type Electrica...

Страница 42: ...then keep the flash drive as a backup copy For this purpose the BST USB flash drives with SLC flash are designed for a particularly long data preservation For more information on the function of the...

Страница 43: ...SSD from the PC by pulling forcefully on the protruding Beckhoff sticker see fig 27 BECKHOFF BECKHOFF BECKHOFF BECKHOFF Fig 27 C6930_SSD replacement 2 Insert the new SSD into the PC in the same orient...

Страница 44: ...You can replace the fan cartridge while the PC is running Insert the new cartridge immediately after removing the old one To change the fan cartridge follow the steps below which are shown in fig 28...

Страница 45: ...PC Other cause Check the power supply cable Call Beckhoff Service The Industrial PC does not boot fully Setup settings are incorrect Other cause Check the setup settings Call Beckhoff Service Computer...

Страница 46: ...vibration EN 60068 2 6 10 to 58 Hz 0 035 mm 58 to 500 Hz 0 5 G approx 5 m s2 Shock resistance shock EN 60068 2 27 5 G approx 50 m s2 duration 30 ms EMC interference immunity conforms to EN 61000 6 2 E...

Страница 47: ...PC which can be found on the name plate Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with...

Страница 48: ...igned to provide adequate protection against adverse interference if the device is used in a commercial environment This device generates uses and may emit radio frequency energy and may cause adverse...

Страница 49: ...mounting plate 1 21 Fig 14 C6930_Dimensions with mounting plate 2 21 Fig 15 C6930_Dimensions with mounting plate 3 and plug in card slots 21 Fig 16 C6930_Dimensions with mounting plate 4 and plug in c...

Страница 50: ...Table 6 USB interface pin assignment 12 Table 7 DVI interface pin assignment 13 Table 8 RS232 pin assignment 13 Table 9 C6930 interface options 14 Table 10 Ordering options plug in card slots 15 Table...

Страница 51: ......

Страница 52: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com C6930...

Отзывы: