background image

 

 
 
 

Installation and Operating instructions for 

Control Cabinet PCs C63xx  -0030 
 -0040 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Version: 1.3 
Date: 2011-02-21

StockCheck.com

Содержание C63 Series

Страница 1: ...Installation and Operating instructions for Control Cabinet PCs C63xx 0030 0040 Version 1 3 Date 2011 02 21 S t o c k C h e c k c o m...

Страница 2: ...S t o c k C h e c k c o m...

Страница 3: ...ansport 13 Unpacking 13 Installation of the PC in the control cabinet 14 Power Supply Connection 15 Pin assignment of the connector 15 Fitting the cable 16 Material for assembling the connectors 16 As...

Страница 4: ...ranches and partner companies 24 Beckhoff Headquarters 24 Beckhoff Support 24 Beckhoff Service 24 Assembly dimensions 25 Appendix 31 Technical data 31 Approvals 32 FCC Federal Communications Commissio...

Страница 5: ...443 BGB of the German Civil Code or a statement about the contractually expected fitness for a particular purpose in the meaning of 434 par 1 sentence 1 BGB In the event that it contains technical or...

Страница 6: ...must first be switched off after which the Industrial PC can be uncoupled from the plant Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that have been switched...

Страница 7: ...ulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of such machines and plant...

Страница 8: ...iguration of the processor Structure C6320 C6330 Configuration with 3 PCI Slots Example Front view of Industrial PC C6330 in basic configuration Opening the housing To open the PC housing release the...

Страница 9: ...sing The power supply is located in the lower part of the chassis 1 the 2 5 hard disk is located in the upper part 2 The slot motherboard 3 is located in the second slot of the housing The Slim Line C...

Страница 10: ...open the PC housing release the screw 1 by one turn using a screwdriver The plastic cap 2 can be then be pulled forward thereby releasing the lid 3 Top view of the open housing The aluminium lid can n...

Страница 11: ...sing The power supply is located in the lower part of the chassis 1 the 2 5 hard disk is located in the upper part 2 The slot motherboard 3 is located in the second slot of the housing The Slim Line C...

Страница 12: ...housing To open the PC housing release the screw 1 by one turn using a screwdriver The plastic cap 2 can be then be pulled forward thereby releasing the lid 3 Top view of the open housing The alumini...

Страница 13: ...ssis can now be removed from the housing The power supply is located in the lower part of the chassis 1 the 2 5 hard disk is located in the upper part 2 The slot motherboard 3 is located in the second...

Страница 14: ...ith VGA input the adapter C9900 Z411 or C9900 Z413 is required additionally C9900 Z411 Adapter plug DVI I to VGA C9900 Z413 Adapter cable DVI I to DVI and VGA 15cm USB interface USB3 An additional USB...

Страница 15: ...ture make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time...

Страница 16: ...enclosure adequate space for ventilation and for opening the PC must be provided Warning Extreme environmental conditions should be avoided as far as possible Protect the PC from dust moisture and he...

Страница 17: ...g the battery pack C9900 U330 Danger Danger of Explosion if using other battery packs Pin assignment of the connector The power supply and the external circuit for switching the Industrial PC on and o...

Страница 18: ...or 16 A and can lift conductive cross sections until 1 5 mm2 Fitting the connector to the cable So the connector is fitted to the cable 1 Strip insulation from the cable ends Length of stripped conduc...

Страница 19: ...se The power supply must be protected with maximum 16 A PC_ON Power Status UPS output The circuit for shutting down the Industrial PC is realized using the input signal PC_ON and the output signal Pow...

Страница 20: ...iring diagram the circuit of PC_ON and Power Status is symbolical Wiring diagram power supply and external circuit i Note The battery pack can only be connected when the Industrial PC is provided with...

Страница 21: ...ices that are to be connected Disconnect all the devices that are to be connected from the power supply Connect all the cables between the Industrial PC and to the devices that are to be connected Con...

Страница 22: ...writing a file to the hard disk the file will be destroyed Control software typically writes something to the hard disk every few seconds so that the probability of causing damage by switching off whi...

Страница 23: ...laced according to the rules of the board manufacturer Danger Danger of Explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer Dispose o...

Страница 24: ...D provided Installation on the PC Installation To install the UPS driver software execute file Beckhoff_UPS_vx xx xx exe from the subdirectory of UPS from the CD provided on the Industrial PC Driver a...

Страница 25: ...y key Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the plant outside...

Страница 26: ...415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Beckhoff offers you comprehensive technical assistance helping you not only with the application...

Страница 27: ...dustrial PCs with dimensions in mm Warning The assembly of the unit must take place with the orientation diagrammed here Industrial PC C6320 Mounting plate at the rear panel front view side view Mount...

Страница 28: ...sembly of the unit must take place with the orientation diagrammed here Industrial PC C6325 Mounting plate at the rear panel Mounting plate at the side panel front view side view side view front view...

Страница 29: ...sembly of the unit must take place with the orientation diagrammed here Industrial PC C6330 Mounting plate at the rear panel front view side view Mounting plate at the side panel side view front view...

Страница 30: ...sembly of the unit must take place with the orientation diagrammed here Industrial PC C6335 Mounting plate at the rear panel front view side view Mounting plate at the side panel side view front view...

Страница 31: ...sembly of the unit must take place with the orientation diagrammed here Industrial PC C6340 Mounting plate at the rear panel front view side view Mounting plate at the side panel front view side view...

Страница 32: ...sembly of the unit must take place with the orientation diagrammed here Industrial PC C6350 Mounting plate at the rear panel front view side view Mounting plate at the side panel front view side view...

Страница 33: ...ation EN 60068 2 6 10 to 58 Hz 0 035 mm 58 to 500 Hz 0 5 G 5 m s2 During reading of CD ROM 10 to 58 Hz 0 019 mm 58 to 500 Hz 0 25 G 2 5 m s2 Impact EN 60068 2 27 29 5 G 50 m s duration 30 ms During re...

Страница 34: ...s equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operati...

Отзывы: