4.1  Switching the Industrial PC on and off 

4.1.1 Switch on 

The Industrial PC does not have its own mains switch. The Industrial PC will start when the equipment is 
switched on, or when it is connected to the power supply. 

4.1.2  Shutting down and switching off 

When the plant is switched off, or when it is disconnected from its power supply, the Industrial PC will be 
switched off. 

Control software such as is typically used on Industrial PCs permits various users to be given different 
rights. A user who may not close software may also not switch the Industrial PC off, since data can be 
lost from the hard disk by switching off while software is running. 
 

First shut down, then switch off the PC 

 

Attention 

If the Industrial PC is switched off as the software is writing a file to the memory drive, 
the file will be destroyed. Control software typically writes something to the memory 
drive every few seconds, so that the probability of causing damage by switching off 
while the software is running is very high. 

 

Switch off power supply 

 

Attention 

When you have shut down the Industrial PC, you have to switch off power supply for at 
least 10 seconds before rebooting the system. 

After resetting power supply the PC will start booting automatically. 

 

4.1.3  First switching on and driver installation 

When you switch on the Industrial PC for the first time, the pre-installed operating system (optional) will 
be started. In this case, all the required drivers for any additional, optional hardware components ordered 
with the PC will already have been installed. 

If the PC was ordered without operating system, you have to install the operating system and the driver 
software for any auxiliary hardware yourself. Please follow the instructions in the documentation for the 
operating system and the additional devices. 

 

20

 

C6030-0060 

Содержание C6030-0060

Страница 1: ...Installation and Operating instructions for C6030 0060 Ultra compact Industrial PC Version 1 1 Date 2018 11 23...

Страница 2: ......

Страница 3: ...oduct overview 7 2 2 Appropriate Use 9 2 3 Access to the connectors 9 2 4 Interfaces 10 2 4 1 Power Supply X101 10 2 4 2 Network connection LAN1 LAN2 LAN3 LAN4 X102 X105 10 2 4 3 USB3 0 interfaces X10...

Страница 4: ...20 4 1 2 Shutting down and switching off 20 4 1 3 First switching on and driver installation 20 4 2 Servicing and maintenance 21 4 2 1 Cleaning of the Industrial PC 21 4 2 2 Maintenance 21 4 2 3 Repla...

Страница 5: ...and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could viol...

Страница 6: ...als Risk of injury WARNING If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safety...

Страница 7: ...fter which the Industrial PC is to be disconnected from the equipment Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that have been switched off must be secured...

Страница 8: ...ing Attention The operator is responsible for ensuring that only trained electrical staff opens the housing of the Industrial PC 1 4 1 National regulations Depending on the type of machine and plant i...

Страница 9: ...developed in line with the high standards Beckhoff is known for such as industrial suitability manufacturing Made in Germany reliability and premium look and feel With integrated multi core support th...

Страница 10: ...l PC for space saving control cabinet installation mounting plate on the rear wall for the free alignment of the connecting area all connectors on the same level aluminium zinc die cast housing Status...

Страница 11: ...control cabinet installation Risk of explosion Danger The Industrial PC must not be used where there is a risk of explosion 2 3 Access to the connectors The connectors of the Industrial PC are located...

Страница 12: ...LAN1 LAN2 LAN3 LAN4 X102 X105 The RJ 45 connectors X102 X105 allow the PC to be connected to a 100 1000 BASE T Local Area Network LAN 2 4 3 USB3 0 interfaces X106 X109 The USB interfaces X106 X109 are...

Страница 13: ...disconnect the ground connection when switching off the device Always disconnect the 24V cable other wise electricity can still flow due to the screen in dependence of the device Any connected devices...

Страница 14: ...10 screws see arrows Now you have access to the battery 1 and the memory devices 2 memory devices 2 battery 1 pole Danger of Explosion WARNING Replace battery only with the identical type or an altern...

Страница 15: ...ng the fan Identical fan type Attention Replace the fans only with the identical type or an alternative type approved by Beckhoff First remove the two red self adhesive flaps at the top and the bottom...

Страница 16: ...n After removing the two Torx TX20 screws see arrows the fan can be exchanged Therefor disconnect the supply cable from the motherboard After exchanging the fan the reassembly takes place in reverse o...

Страница 17: ...e condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hours m...

Страница 18: ...at the rear wall C9900 M669 Only mounting sheet for side wall installation The mounting sheets are fastened at the Industrial PC using Torx screws of size TX10 3 2 2 Preparation of the control cabinet...

Страница 19: ...n of the power supply wiring with a cable cross section of 1 5 mm2 must be used With bigger distances between voltage source and PC you take the voltage drop as a function of the cable cross section a...

Страница 20: ...connected to 24 V via a switch the PC shuts down according to the rules The PC_ON signal is inverted i e the PC shuts down if the 24 V connection is live Once the PC has shut down the Power Status out...

Страница 21: ...pply Connect all the cables between the Industrial PC and to the devices that are to be connected Connect all data transfer cables if present to the appropriate plug in receptacles of the data telecom...

Страница 22: ...emory drive the file will be destroyed Control software typically writes something to the memory drive every few seconds so that the probability of causing damage by switching off while the software i...

Страница 23: ...ed by the manufacturer Notice correct polarity Handling of Lithium Batteries WARNING Lithium Batteries should not be recharged exposed to fire opened and they should be protected against sunlight and...

Страница 24: ...Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the plant outside the Industrial PC Call the ma...

Страница 25: ...imensions Industrial PC C6030 0060 with mounting sheet for rear wall installation Notice mounting orientation Attention The assembly of the unit must take place with the orientation diagrammed here Al...

Страница 26: ...ndustrial PC C6030 0060 with mounting sheet for side wall installation Notice mounting orientation Attention The assembly of the unit must take place with the orientation diagrammed here All dimension...

Страница 27: ...idal vibration EN 60068 2 6 10 to 58 Hz 0 035 mm 58 to 500 Hz 0 5 G 5 m s2 Shock resistance Shock EN 60068 2 27 5 G 50 m s2 duration 30 ms EMC compatibility Resistance to interference conforms to EN 6...

Страница 28: ...KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive technical assista...

Страница 29: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this e...

Отзывы: