5.5
Warning messages
Faults which occur, but which do not cause a switch-off of the amplifier output stage
(BTB/RTO contact remains closed), are indicated in the LED display on the front panel by
a coded warning number.
Number
Designation
Explanation
A/I/P/E
Status message
status message, no error, see page 65
. . .
Status Message
amplifier is updating the startup configuration
n01
I²t
I²t threshold exceeded
n02
regen power
reached preset regen power limit
n03*
S_fault
exceeded preset following error limit
n04*
response monitoring
response monitoring (fieldbus) has been
activated
n05
supply phase
supply phase missing
n06*
Sw limit-switch 1
passed software limit-switch 1
n07*
Sw limit-switch 2
passed software limit-switch 2
n08
motion task error
a faulty motion task was started
n09
no reference point
no reference point set at start of motion task
n10*
PSTOP
PSTOP limit-switch activated
n11*
NSTOP
NSTOP limit-switch activated
n12
default values
only for HIPERFACE
®
:
motor default values loaded
n13*
expansion card
expansion card not operating correctly
n14
SinCos feedback
SinCos commutation failure
n15
table fault
fault as per speed/current table INXMODE 35
n16
Summarized warning
Summarized warning for n17 to n31
n17
Fieldbus-Sync
Fieldbus not synchronized
n18
Multiturn overflow
Max. number of motor turns exceeded
n19-n31
reserve
reserve
n32
firmware beta version
firmware version has not been released
* = these warning messages result in a controller shut-down of the drive (braking by
emergency stop ramp)
AX2500 Installation Manual
67
Beckhoff
02/06
Setup
Содержание AX2500 Series
Страница 22: ...This page has been deliberately left blank 22 AX2500 Installation Manual Technical description 02 06 Beckhoff...
Страница 26: ...3 3 1 Dimensions 26 AX2500 Installation Manual Installation 02 06 Beckhoff AX250x and AX251x AX252x...
Страница 31: ...3 4 4 Connector assignments AX2500 Installation Manual 31 Beckhoff 02 06 Installation...
Страница 36: ...This page has been deliberately left blank 36 AX2500 Installation Manual Installation 02 06 Beckhoff...
Страница 60: ...This page has been deliberately left blank 60 AX2500 Installation Manual Interfaces 02 06 Beckhoff...
Страница 65: ...5 3 2 3 Status display on the master AX2500 Installation Manual 65 Beckhoff 02 06 Setup...
Страница 68: ...This page has been deliberately left blank 68 AX2500 Installation Manual Setup 02 06 Beckhoff...