background image

Assembly instructions | EN

AX2090-BW65

External IP 65 braking resistors

7/5/2021 | Version 1.0

Содержание AX2090-BW65

Страница 1: ...Assembly instructions EN AX2090 BW65 External IP 65 braking resistors 7 5 2021 Version 1 0...

Страница 2: ......

Страница 3: ...18 Intended use 19 Technical data 20 Data for operation and environment 20 AX2090 BW65 04xx 21 AX2090 BW65 15xx 22 Scope of supply 23 Transport and storage 24 Conditions 24 Transport 25 Long term sto...

Страница 4: ...CAT EtherCAT G EtherCAT G10 EtherCAT P Safety over EtherCAT TwinSAFE XFC XTS and XPlanar are registered and licensed trademarks of Beckhoff Automation GmbH The use of other brand names or designations...

Страница 5: ...nd nullify the liability of Beckhoff Automation GmbH Co KG The following is excluded from the liability Failure to observe these operating instructions Improper use Use of untrained personnel Use of u...

Страница 6: ...uest to info beckhoff de Origin of the document These operating instructions were originally written in German All other languages are derived from the German original Product properties Only the prod...

Страница 7: ...equirements including all appli cable laws regulations provisions and standards Instructed person Instructed persons have a clearly defined task area and have been informed about the work to be carrie...

Страница 8: ...or technical train ing They have an understanding of control technology and automa tion They are familiar with relevant standards and directives Quali fied electricians can independently recognize av...

Страница 9: ...gement The triangle indicates instructions that you should execute The bullet point indicates an enumeration The square parentheses indicate cross references to other text passages in the document The...

Страница 10: ...a which you can view videos ani mations or other documents Internet access is required in order to use it You can read the QR code for example with the camera of your Smartphone or Tablet PC If your c...

Страница 11: ...remises Hotline 49 0 5246 963 5000 Fax 49 0 5246 963 95000 E mail training beckhoff com Web www beckhoff de training 1 6 3Service The Beckhoff Service Center supports you with after sales services suc...

Страница 12: ...careless or incorrect use Work particularly thor oughly not under time pressure and responsibly towards other peo ple 2 1Safety pictograms Beckhoff products feature safety pictograms either on sticker...

Страница 13: ...hine parts Shut down and secure the machine or plant Shut down the machine or plant Secure the machine or plant against being inadvertently started up Correctly ground electrical components or modules...

Страница 14: ...d to 50 V Ensure that the protective conductor is connected properly Never loosen electrical connections when live Disconnect all components from the mains and secure them against being switched on ag...

Страница 15: ...Product overview Version 1 0 15 AX2090 BW65 3 Number Explanation 1 Housing 2 Name plate 3 Electrical connection 4 Fastening to the mounting surface...

Страница 16: ...12 13 Number Explanation 1 Article description 2 Product type 3 Order number 4 Date of manufacture 5 Internal ID 6 Technical data Resistance value power rating voltage 7 Protection class 8 Not releva...

Страница 17: ...on AX2090 Product area Drive Technology Accessories BW Brake energy management Brake resistor 65 Series IP65 all devices in the AMP8000 AX8000 and AX5000 series xx Power 04 400 W 15 1500 W yy Resistan...

Страница 18: ...tection means that the braking resistors are designed for protection from dust dirt and moisture caused by water jets when mounted outside the control cabinet UL and CSA marking The braking resistors...

Страница 19: ...000 multi axis servo system or Original operating instructions for the distributed servo drive system AMP8000 or Original operating instructions for the AX5000 servo drive Complete machine documentati...

Страница 20: ...sport 15 C to 70 C maximum fluctuation 20 K hour Ambient temperature during storage 15 C to 70 C maximum fluctuation 20 K hour Power derating No power derating up to 1000 m above sea level Power derat...

Страница 21: ...W65 04xx Electrical data AX2090 BW65 04xx 18 23 33 47 Type power at 40 C W 4 power derating per 10 K temperature difference 400 400 400 400 Resistance 18 23 33 47 Mechanical data AX2090 BW65 04xx Weig...

Страница 22: ...5 15xx Electrical data AX2090 BW65 15xx 18 23 33 47 Type power at 40 C W 4 power derating per 10 K temperature difference 1500 1500 1500 1500 Resistance 18 23 33 47 Mechanical data AX2090 BW65 15xx We...

Страница 23: ...issing or damaged parts Check your delivery for completeness If any parts are missing or became damaged during transport contact the carrier vendor or our service department immediately Please check t...

Страница 24: ...in the brake resistor Slowly adjust the temperature to room temperature Switch the brake resistor on only when it is dry If the brake resistor is not fully dry condensed water can lead to a short cir...

Страница 25: ...e transported without any aids 6 3Long term storage Observe the maximum storage time Do not exceed a maximum storage time of five years Exceeding the specified maximum storage time can lead to a chang...

Страница 26: ...position Due to heat generation the vertical installation position A is only permitted if the electrical connection points downwards Failure to comply may result in damage to the connecting cable and...

Страница 27: ...g voltage of 848 VDC on the capaci tors after disconnection from the supply network Serious or even fatal injuries may result if this is ignored Electromagnetic compatibility Connect all components an...

Страница 28: ...les are tested with regard to the ma terial used shielding and connection type Perfect functioning and compliance with legal regulations such as EMC and UL are guar anteed The use of other cables can...

Страница 29: ...le 8 2 1 Position Explanation 1 Switch on time ton 2 Cycle time The duty cycle is a relative value and depends on the switch on time ton and the cycle time A cycle time of up to 120 seconds is incorpo...

Страница 30: ...ake resistor is adequately ventilated Failure to comply may result in severe skin burns and or destruc tion of the braking resistor or adjacent components Position Explanation x Continuous power in of...

Страница 31: ...m 160 Still permissible operation with short service life and high failure probability Impermissible Over 160 Risk of destruction of the brake resistor due to overheating and endangerment of the surro...

Страница 32: ...r switching off Ignoring this can lead to burns being sustained Do not immerse or hose down the brake resistor Only wipe the brake resistor with a cloth Cleaning by immersion will destroy the brake re...

Страница 33: ...Accessories Version 1 0 33 AX2090 BW65 10 1Touch protection 10 1 The touch guard provides protection from hot surface temperatures on the braking resistors...

Страница 34: ...AMP8620 2005 0x00 30 minutes for AMP8805 1000 0000 30 minutes for AX8831 30 minutes for AX8832 5 minutes for AX5101 to AX5125 and AX5172 15 minutes for AX5140 AX5160 and AX5172 30 minutes for AX5190...

Страница 35: ...electrical power drive systems EMC require ments and specific test methods Product standard EN 61800 5 1 2007 A1 2017 Adjustable speed electrical power drive systems Safety require ments RoHS EN 5058...

Страница 36: ...hine or system The AX2090 BW65 xxxx braking resistor complies with UL requirements and is certified as cURus component for the US and Canadian markets in ac cordance with the standards applicable in t...

Страница 37: ...M Maintenance 32 N Name plate 16 O Operating Conditions 20 Overtemperature 30 P Pictograms 9 Power derating 20 Protection class IP65 18 S Safety 12 De energized and voltage free condition 14 Discharge...

Страница 38: ......

Страница 39: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com...

Отзывы: