9.7
Warning messages
Faults which occur, but which do not cause a switch-off of the amplifier output stage (BTB/RTO con-
tact remains closed), are indicated in the LED display on the front panel by a coded warning
number.
Number
Designation
Explanation
E / S / A / P
Status Messages
Status messages, no error, see p. 90
. . .
Status Message
Updating the startup configuration
-
Status Message
Programming mode
n01
I²t
I²t threshold exceeded
n02
Regen power
Reached preset regen power limit
n03*
S_fault
Exceeded preset following error limit
n04*
Response monitoring
Response monitoring (fieldbus) has been activated
n05
Supply phase
Mains supply phase missing
n06*
SW limit switch 1
Underrun software limit switch 1
n07*
SW limit switch 2
Overrun software limit switch 2
n08
Motion task error
A faulty motion task was started
n09
No reference point
No reference point (Home) set at start of motion task
n10*
PSTOP
PSTOP limit-switch activated
n11*
NSTOP
NSTOP limit-switch activated
n12
Motor default values
loaded
Only for ENDAT or HIPERFACE
®
:
discrepancy between motor number saved in the en-
coder and the amplifier, motor default values loaded
n13*
Slot warning
24V supply of the I/O expansion board is missing
n14
SinCos feedback
SinCos commutation (wake & shake) not completed,
will be canceled when amplifier is enabled and
wake&shake carried out
n15
Table error
Fault according to speed/current table INXMODE 35
n16
Summarized warning
Summarized warning for n17 to n31
n17
Fielbus Synchronization
The mode synchronization SYNCSRC is selected but
the drive isn’t in synchronies cycle
n18
Multiturn overrun
Using Multiturn encoder feedback, an overrun over
the maximum number of resolutions was detected
n19
Motion task ramps are limited
Range overflow on motion task data
n20
Wrong GMT data
Wrong "Graphical Motion Task" data
n21
PLC program error
For details see plc code
n22
max. motor temperatur rea-
ched
The user can shut down the process before the tem-
perature eror will interrupt the process immediately
n23...n31
reserved
reserved
n32
firmware beta version
Firmware is an unreleased beta version
* = These warning messages lead to a controlled shut-down of the drive (braking with the emergency ramp)
More information to the messages can be found in the ASCII Object Reference
(Online Help), see parameter STATCODE. Hints for removal can be found in section
"Trouble-Shooting" of the online help.
AX2040/2070 Product Manual
93
BECKHOFF
06/2007
Setup
Содержание AX2040
Страница 35: ...7 4 Dimensions AX2040 2070 Product Manual 35 BECKHOFF 06 2007 Mechanical Installation...
Страница 44: ...8 6 Pin assignments 44 AX2040 2070 Product Manual Electrical Installation 06 2007 BECKHOFF...
Страница 108: ...This page has been deliberately left blank 108 AX2040 2070 Product Manual Expansion Cards 06 2007 BECKHOFF...