Technical description
Version: 1.0
───
35
AMI8100
7.1
Mounting position
Observe the maintenance intervals and installation positions
Carry out maintenance at regular intervals.
In the horizontal installation position IM V3, liquid which has been
left on the flange for a longer period can penetrate the servo drive
through capillary action. In installation position IM V1 liquid can es-
cape.
If you do not observe the maintenance intervals, the servo drive
may overheat depending on the installation position. Ingress and
leakage of liquids may damage the servo drive.
The standard installation position of the servo drives is the design
IM B5 according to DIN EN 60034-7.
7.2
Feedback
Feedback exchange
The feedback system installed can only be replaced with an identi-
cal system. It is not possible to change the feedback system retro-
spectively.
The table below provides information about system accuracies and
resolutions of the servo drive feedback systems:
Feedback
Resolution
System accuracy
Comment
Encoder, single-turn
Encoder, multi-turn
17-bit
± 316 angular seconds
Standard:
AMI812x