background image

 

        
  
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

UV FILTER PUMP KIT INSTRUCTIONS 

MODEL: M130UV 

 

92095 
Rev. C 

 

CAUTION! 

 

Do not look directly at UV lamp. 

 

As the pump

 

circulates water through the filter the UV exposure produces clean clear water.  

 

Beckett pumps are carefully inspected and tested to ensure both safety and operating performance. However, failure to follow the instructions and warnings in 
this manual may result in pump damage and/or serious injury. Be sure to read and save this manual for future reference. 

 

Performance:     130GPH 

Power Requirements:   120V,60Hz,13 Watts 

Shut off (max):         4.3ft 

Cord Length:                 16ft 

 

 

 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 

               SAVE THIS MANUAL FOR FUTURE REFERNCE 

WARNING 

 

The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying water pumps. See your electrical 
supplies dealer for this device. 

 

Do not remove the grounding pin from the plug. 

 

Do not connect to any voltage other than shown on the pump. 

 

Do not pump flammable liquids. 

 

Do not use with water above 86º Fahrenheit (30ºC). 

 

To reduce the risk of electric shock, use only on portable self-contained fountains no larger than 5 feet in any dimension. 

 

Risk of electrical shock. This pump is supplied with a grounding conductor and ground attachment plug. To reduce the risk of electric shock, be certain 
that it is connected only to a properly grounded, grounding-type receptacle. 

 

Ensure that the electrical cord loops below the electrical outlet to form a “Drip Loop”.  This will prevent water from running down the cord into the 
electrical outlet. 

 

Never directly touch the UV bulb – oil from your fingers can shorten bulb life. 

 

If the UV’s internal components get wet, unplug the unit immediately. 

 

Do not operate the UV Assembly with a missing or damaged Quartz sleeve. 

 

The pump cover is provided with an interlock to reduce the risk of excessive ultraviolet radiation. Do not defeat its purpose or attempt to service without 
removing the screen cover completely. 

 

 

                                   

CAUTION 

 

Always disconnect from electrical outlet before handling the pump.      

 

Do not let the pump run dry.      

 

Do not lift the pump by the power cord. 

 

Do not pump heated liquids. 

 

Operate in freshwater only. 

 

Operate pump completely submerged for proper cooling. 

 

Do not look directly at UV lamp. 

 

                                 

 ATTENTION 

In order to get best results, operate pump completely submerged. Keep 
 the water level above the top of the pump at ALL TIMES

Parts Detail: 

 
1)  Enclosure housing  
 
2)  Grid 
 
3)  Volute Cover 
 
4)  O-rings 
 
5)  Impeller 
 
6)  Cap with power cord 
 
7)  3 watt UV bulb (E17) 
 
8)  Quartz Glass 
 
9)  Rubber Seal 
 
10) Seal Nut 

 
 
 

 

 

 

Содержание M130UV

Страница 1: ... shock This pump is supplied with a grounding conductor and ground attachment plug To reduce the risk of electric shock be certain that it is connected only to a properly grounded grounding type receptacle Ensure that the electrical cord loops below the electrical outlet to form a Drip Loop This will prevent water from running down the cord into the electrical outlet Never directly touch the UV bu...

Страница 2: ...IONS CONTAINED IN THIS PARAGRAPH SHALL NOT APPLY TO INJURY TO THE PERSON Some States do not allow the exclusion or limitation of incidental or consequential damages or exclusions or limitations on the duration of an implied warranty so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from State to St...

Страница 3: ... No haga caso omiso a su propósito o intente utilizarlo sin quitar por complete la cubierta PRECAUCION Desconecte siempre de la toma de corriente eléctrica antes de manipular la bomba No permita que la bomba trabaje sin agua No levante la bomba tomándola por el cable No bombee líquidos calientes Haga que funcione sólo en agua potable Para que la bomba se enfríe correctamente ésta siempre debe trab...

Страница 4: ...bas a una temperatura normal 32º F a 86º F 0º C a 30º C con una la especificación gravitacional de hasta 1 1 y con un pH dentro del rango de 5 a 9 agua fresca Cualquier otra aplicación de líquidos o uso de temperaturas extremas debe ser aprobado previamente por Beckett La garantía no aplica o cubre daños o defectos causados por causas externas incluyendo pero no limitándose a instalación inapropia...

Страница 5: ...ent mise à la terre Assurez vous que le câble électrique forme une boucle d égouttement sous la prise En cas de fuite cette boucle évitera que l eau ne coule le long du câble et ne pénètre dans la prise Ne jamais toucher directement une ampoule UV l huile présente sur les mains peut réduire la durée de l ampoule Si les composants internes du stérilisateur UV entrent en contact avec de l eau débran...

Страница 6: ...ée et est limitée à l application à la température normale de 32º F à 86º F 0º C à 30º C de fluides de pompage dont la gravité spécifique maximale est de 1 1 et dont le pH se situe entre 5 et 9 eau douce Les autres applications de liquide et les utilisations à des températures extrêmes doivent être approuvées à l avance par Beckett La garantie ne s applique pas à des dommages ou à des défauts caus...

Страница 7: ......

Отзывы: