background image

Form No. 61765 R03, Printed in USA 08/10

CORPORATION

USA:

  P.O. Box 1289 

 Elyria, OH  44036

Canada:

  R.W. Beckett Canada, Ltd. 

 Unit #3, 430 Laird Road 

 Guelph, Ontario N1G 3X7

www.beckettcorp.com

The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who 
purchase its “Products” from Beckett for resale, or for incorporation into a 
product for resale (“Customers”), that its equipment is free from defects in 
material and workmanship. To qualify for warranty bene

fi

 ts, products must be 

installed by a quali

fi

 ed service agency in full compliance with all codes and 

authorities having jurisdiction, and used within the tolerances of Beckett’s 
de

fi

 ned product speci

fi

 cations. 

To review the complete warranty policy and duration of coverage for a speci

fi

 c 

product, or obtain a written copy of warranty form 61545, please choose one of 
the following options:

Visit our website at: www.beckettcorp.com/warranty 

Email your request to:  [email protected]

Write to:  R. W. Beckett Corporation, P. O. Box 1289, Elyria, OH 
44036

NOTE:  Beckett is not responsible for any labor cost for removal 
and replacement of equipment.

THIS WARRANTY IS LIMITED TO THE PRECISE TERMS SET FORTH 
ABOVE, AND PROVIDES EXCLUSIVE REMEDIES EXPRESSLY IN LIEU 
OF ALL OTHER REMEDIES, AND IN PARTICULAR THERE SHALL BE 
EXCLUDED THE IMPLIED WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT WILL BECKETT 
BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGE OF ANY 
NATURE.  Beckett neither assumes, nor authorizes any person to assume 
for Beckett, any other liability or obligation in connection with the sale of this 
equipment. Beckett’s liability and Customer’s exclusive remedy is limited to the 
cost of the product.

1.

2.

3.

Limited Warranty Information

Содержание GeniSys 24V 7559

Страница 1: ...water heaters pressure washers crack sealers and portable heaters having firing rates less than 5 5 GPH The GeniSysTM 24V is used with a suitable cad cell flame sensor to control the oil burner motor...

Страница 2: ...GPH CAUTION A low or erratic power supply could result in impaired burner operation severe delayed ignition or an explosion inside the heat exchanger resulting in a burn and or asphyxiation hazard Mai...

Страница 3: ...ment Skilled in the adjustment of oil burners using combustion test instruments The installation must strictly comply with all applicable codes authorities having jurisdiction and the latest revision...

Страница 4: ...know the control SK10048 24V POWER MAIN ALARM VALVE GND VLV IGNITER GND IGN MOTOR GND MTR ENABLE CAD CELL ON OFF RESET HIGH LIMIT MOTOR IGNITER THERMOSTAT CAD CELL RED WIRE BLACK WIRE OIL VALVE Cad C...

Страница 5: ...remove the cad cell jumper Simulate Flame Failure and Ignition Failure Refer to the steps for Starting the System and have the system call for heat After flame is established and the burner igniter t...

Страница 6: ...hed the igniter remains on for 10 additional seconds to ensure flame stability Run The flame is sustained until the call for heat is satisfied The control then switches to Motor Off Delay if applicabl...

Страница 7: ...oil and oil vapor before starting or resetting the burner y y y y Failure to bleed the pump properly could result in unstable combustion hot gas puff back and heavy smoke Hot Gas Puff Back Heavy Smoke...

Страница 8: ...y of warranty form 61545 please choose one of the following options Visit our website at www beckettcorp com warranty Email your request to rwb customer service beckettcorp com Write to R W Beckett Co...

Отзывы: