Beckett CF1400 Скачать руководство пользователя страница 22

22

Item

Part Name

Description

CF1400 

Part No.

CF2300 

Part No.

1

Oil Valve

Mounted on Junction Box

21789U

21789U

2

Knurled Nut

All models

3666

3666

3

Adjusting plate assembly

w/ cast aluminum door

w/ stamped sheet-metal door

51213U

5201701U

51213U

5201701U

4

Fuel pump

B2TA-8245

21313U

21313U

5

Damper motor

2-stage

750601U

750601U

6

Fuel lines

Specify length

7

Air Proving Switch

2” W.C.

22181U

22181U

8

Timer

Nozzle Valve Delay

21295U

21295U

9

Transformer

12,000 volt

51214

51214

10

Control

Specify

11

Pedestal kit

All models

51193

51193

12

Coupling hole plug

use with threaded hole

32439U

32439U

13

Rear cover door as-

sembly

w/ cast aluminum door* 

w/ stamped sheet-metal door*  

5994U

5201301U

51204U

5201302U

14

Sight glass

All models

31346

31346

15

Head assembly

5978

51203

16

Electrode assembly

All models

51212

51212

17

Ignition leads

8-1/4” long

11-3/4” long

15-1/4” long
19-1/4” long

5990082

5990116

5990152
5990192

5990082

5990116

5990152
5990192

18

Air tube

Refer to 

Figure 4

19

Nozzle line assembly

Refer to 

Figure 5

20

Coupling

B Pump

21290

21549

21

Blower wheel

CF1400 - 5.59” x 3.09”
CF2300 - 6.75” x 3.13”

21268U

21267U

22

Motor Mounting Flange

N/A

31347U

23

Motor

120/208-230 single phase 

208-230/460 three phase

21401U
21638U

21402U
21499U

Motor relay (not shown)

120V single phase
208V single phase

Three phase

752804

7300

2194301

752804

7300

2194301

Adjustable 

fl

 ange

See 

Figure 18

 on previous page

* These doors are NOT interchangeable. Please specify when ordering.

Replacement Parts 

For best performance specify genuine

 

Beckett

 replacement parts

Содержание CF1400

Страница 1: ...tion start up or service work Save this manual for future reference y y y Incorrect installation adjustment or misuse of this burner could result in death severe personal injury or substantial propert...

Страница 2: ...which your burner ap pliance is installed Make sure Air ventilation openings are clean and unob structed Nothing is blocking burner inlet air openings No combustible materials are stored near the heat...

Страница 3: ...e read all instructions before proceeding Follow all instructions completely This equipment must be installed adjusted and started by a qualified service agency that is licensed and experienced with a...

Страница 4: ...ed in an isolated room provided with outside combustion air Clearances With the burner installed in the appliance there must be adequate space in front of and on the sides of the burner to allow acces...

Страница 5: ...he appliance dimensions are smaller than recommended reduce the firing rate accordingly Table 1 Nozzle Capacities Rated gph 100 psig Pressure Pounds per square inch 125 140 150 175 200 250 275 300 3 0...

Страница 6: ...ing rate required On the CF2300 there are two tube arrangements available Tube A 7 0 to 19 9 GPH per Figure 3 Tube B 10 0 to 19 9 GPH per Figure 3 The CF2300 maximum firing capacity depends on the fir...

Страница 7: ...loss of burner operation resulting in no heat an unplanned process interruption work stoppage and the potential for frozen plumbing or other cold weather property damage Protect Against Dust and Mois...

Страница 8: ...he end of the nozzle line leaving the nut loosely placed so the plates can be moved Connect the high voltage leads from the ignition transformer to the electrodes Check and adjust if necessary the cri...

Страница 9: ...s than dimension D in Figure 8 Thread the pipe into the flange Secure the burner to the appliance by tightening the nuts on the burner flange mounting studs 1 2 3 4 5 6 Figure 7 Adjusting Plate Assy F...

Страница 10: ...ump k Return line to oil tank m One pipe by pass loop 3 8 p Air bleed valve Figure 9 One pipe Oil Flow with B Pump SK9940 Figure 10 Two pipe Oil Flow with B Pump SK9939 Use continuous lengths of heavy...

Страница 11: ...s energized A flame should be established within the factory set trial for ignition time lockout time Lockout The control has shut down for one of the following safety reasons The trial for ignition l...

Страница 12: ...equence The control will continue to Recycle each time the flame is lost until it reaches a pre set time allotment The control will then go into Hard Lockout instead of recycle This feature prevents e...

Страница 13: ...13 CF1400 CF2300 Burner Manual Figure 13 Typical Wiring 7505P Section Wire the Burner...

Страница 14: ...de The burner starts at Low goes to High after the flame stabilization 1 2 3 4 5 6 a period Flame is extinguished when the load is satisfied or a limit opens and the burner is sent to Motor Off Delay...

Страница 15: ...tart up Professional Installation and Service Required Incorrect installation and mishandling of start up could lead to equipment malfunction and result in asphyxiation explosion or fire This burner m...

Страница 16: ...0 6 17 0 60 16 0 7 18 0 70 17 0 8 19 0 80 18 0 9 20 0 90 19 0 100 20 0 B 0 12 5 0 1 13 0 10 10 0 2 14 0 20 13 0 3 15 0 30 14 0 4 16 0 40 15 0 5 17 0 50 16 0 6 18 0 60 17 0 7 18 5 70 18 0 8 19 0 80 18...

Страница 17: ...to its low fire setting This initial setting should be adequate for starting the burner at low fire Once the burner is in operation the air setting will be adjusted for best performance as discussed l...

Страница 18: ...stment Vapor Filled Appliance Allow the unit to cool off and all vapors to dissipate before attempting another start Oil Flooded Appliance Shut off the electrical power and the oil supply to the burne...

Страница 19: ...Burner Move the low fire hold switch to the low fire hold position to hold burner in low fire when started Verify that the air adjusting cam Figure 17 item d has been set to the initial low fire air...

Страница 20: ...3 12 44 DIA 51498 13 92 DIA 51630 16 00 DIA Flange A Flange B Flange C Check the pump pressure and cutoff function Check primary control safety lockout timing Check ignition system for proper operatio...

Страница 21: ...21 CF1400 CF2300 Burner Manual SK9930 3 2 4 5 6 1 SK9931 8 9 7 Section Replacement Parts Figure 19a Burner Replacement Parts...

Страница 22: ...5994U 5201301U 51204U 5201302U 14 Sight glass All models 31346 31346 15 Head assembly 5978 51203 16 Electrode assembly All models 51212 51212 17 Ignition leads 8 1 4 long 11 3 4 long 15 1 4 long 19 1...

Страница 23: ...23 CF1400 CF2300 Burner Manual Figure 19b Burner Replacement Parts Continued SK9936 SK9932 SK9930 14 13 12 10 20 11 21 22 23 15 16 17 18 19...

Страница 24: ...copy of warranty form 61545 please choose one of the following options Visit our website at www beckettcorp com warranty Email your request to rwb customer service beckettcorp com Write to R W Beckett...

Отзывы: