PARTS & ACCESSORIES

Description / Applications

The Beckett AquaSmart™ is an advanced boiler control designed for use on 
residential and light commercial boiler systems. All models include the option of 
enabling Beckett HeatManager™ dynamic temperature reset that, when selected, 
provides up to 20% fuel consumption savings. The control includes a backlit LCD 
digital display with touch pad to easily program temperature limits, differentials, 
and other advanced options. The AquaSmart™ also has memory storage of 
system history for help with diagnostics and troubleshooting.

Содержание AQUASMART 7600

Страница 1: ...de the option of enabling Beckett HeatManager dynamic temperature reset that when selected provides up to 20 fuel consumption savings The control includes a backlit LCD digital display with touch pad...

Страница 2: ...WCO Safety Function 9 Installing the AquaSmart Control 10 Immersion Well or 2 in 1 Sensor 10 Appliance Surface 10 Wiring 10 Wiring the AquaSmart Control 11 Programming Basic Functions 25 A Temperature...

Страница 3: ...4 Technical Specifications Electrical Ratings Input Voltage 120 Vac 50 60 Hz Input Current 0 1 A B1 C1 ZC MAX Input Current 20A Reduce to 15A if optional power disconnect switch is used 24 Vac Thermos...

Страница 4: ...sign aftermarket immersion well with the proper dimensions can be purchased from a HVAC distributor The AquaSmart can then be mounted in the typical way Surface Mounting This is sometimes required and...

Страница 5: ...240 VAC Available operating limit and differential ranges are not equivalent Compare the settings to the AquaSmart ranges before replacing 8F48A 351 8B43A 601 7600B 11C61 12 7600A Not a suitable repl...

Страница 6: ...gs to the AquaSmart ranges before replacing White Rodgers Beckett Replacement Notes 11B06 1 11D18 1 11B18 101 11B30 104 11B02 1 1145 33 7600A or 7600B Based on System Voltage Requirements Make sure 76...

Страница 7: ...ne disconnect switch Burn and Scald Hazard Excessive water temperatures could cause explosion burns scalding pressure relief flooding and fitting leaks Carefully follow the outlined procedures for tem...

Страница 8: ...ontrol operation Make sure the plumbing for domestic hot water has anti scald valve protection Follow all applicable safety codes rules and guidelines for installing an immersion well Improper install...

Страница 9: ...m the 2 in 1 sensor under the ground screw at the bottom of the control Item b Figure 6 Thoroughly clean the pipe surface and securely tighten the pipe clamp on the water inlet pipe to the boiler as c...

Страница 10: ...and put into operation only by a trained licensed qualified professional or service agency in accordance with the latest revision of the National Electric Code ANSI NFPA 70 Canada CSA C22 1 state loca...

Страница 11: ...of the thermostat to the TW terminal on the control y y 7600B only TERMINALS TR Z or hot and B2 TV or ground offer a 24 volt supply for operating other 24 VAC equipment on the boiler IMPORTANT TO PREV...

Страница 12: ...ng 1 Set DHWP OFF default see programming section for instructions 2 Set C1 on TT default see programming section for instructions LOW VOLTAGE THERMOSTAT L2 L1 C1 C2 ZC ZR B1 B2 P1 CIRCULATOR 120 VAC...

Страница 13: ...C1 C2 ZC ZR B1 B2 TR TW SK10020 6 5 4 3 2 N 1 H T T ZONE RELAY ZONE 2 LOW VOLTAGE THERMOSTAT NEUTRAL HOT 120 VAC BLACK WHITE ZONE 1 LOW VOLTAGE THERMOSTAT P1 CIRCULATOR 120 VAC P2 WHITE RED 7600A 120...

Страница 14: ...0B 24 VAC GAS IGNITION SYSTEM FIELD MFR SUPPLIED SERVICE SWITCH P2 CIRCULATOR 120 VAC 6 5 Figure 13 continued 7600A B multi zone connections with or without a tankless coil Control Wiring Option 2 Cir...

Страница 15: ...SK10033 EXPANSION TANK HEATING ZONE 1 AIR VENT HEATING ZONE 2 HEATING ZONE 3 Z Z Z ZONE 1 24 VAC ZONE VALVE ZONE 2 24 VAC ZONE VALVE ZONE 3 24 VAC ZONE VALVE AIR SEPARATOR GENERAL CIRCULATOR COLD WAT...

Страница 16: ...ere are no jumpers between the terminals of the zone valves CONTINUED FROM PREVIOUS PAGE TR TW 120 VAC BURNER OR GAS IGNITION SYSTEM SK10046 L2 L1 C1 C2 ZC ZR B1 B2 NEUTRAL HOT 120 VAC BLACK WHITE CIR...

Страница 17: ...rogramming section for instructions 2 Set C1 on TT default see programming section for instructions 3 Circulator on and off delay will only affect zone 1 L2 L1 C1 C2 ZC ZR B1 B2 TR TW SK10023 6 5 4 3...

Страница 18: ...ATING ZONE 1 INDIRECT DHW DHW ZONE P1 P2 P3 HEATING ZONE 2 HEATING ZONE 3 P4 Figure 16 7600A B multi zone connections with Indirect Domestic Hot Water DHW Water Flow CONTINUED ON NEXT PAGE additional...

Страница 19: ...BURNER OR GAS IGNITION SYSTEM 7600B 24 VAC GAS IGNITION SYSTEM L2 L1 C1 C2 ZC ZR B1 B2 TR TW SK10022 6 5 4 3 2 N 1 H T T ZONE RELAY ZONE 1 LOW VOLTAGE THERMOSTAT LOW VOLTAGE THERMOSTAT ZONE 2 ZONE REL...

Страница 20: ...NITION SYSTEM 7600B 24 VAC GAS IGNITION SYSTEM FIELD MFR SUPPLIED SERVICE SWITCH 5 6 Figure 16 continued 7600A B multi zone connections with Indirect Domestic Hot Water DHW CONTINUED FROM PREVIOUS PAG...

Страница 21: ...ll other zones will heat to the reset temperature determined by the HeatManager 5 Ensure that the zone panel and AquaSmart are powered from the same service switch DHW LIMIT CONTROL L2 L1 C1 C2 ZC ZR...

Страница 22: ...NE 1 AIR SEPARATOR AIR VENT HEATING ZONE 2 HEATING ZONE 3 Z Z Z ZONE 1 24 VAC ZONE VALVE ZONE 2 24 VAC ZONE VALVE ZONE 3 24 VAC ZONE VALVE GENERAL CIRCULATOR DHW ZONE INDIRECT DHW Z DHW ZONE 24 VAC ZO...

Страница 23: ...the terminals of the zone valves CONTINUED FROM PREVIOUS PAGE TH TR TR TW 24 VAC GAS IGNITION SYSTEM ZONE 1 LOW VOLTAGE THERMOSTAT ZONE 1 24 VAC ZONE VALVE T Z TV SK10038 L2 L1 C1 C2 ZC ZR B1 B2 NEUTR...

Страница 24: ...ALVE SK10047 L2 L1 C1 C2 ZC ZR B1 B2 NEUTRAL HOT 120 VAC BLACK WHITE CIRCULATOR 120 VAC GENERAL CIRCULATOR TR TH Honewell V8043F ZONE RELAY T T 1 H 2 N 3 4 5 6 DHW ZONE 24 VAC ZONE VALVE Y R R Y ZONE...

Страница 25: ...5 at a time The control will not allow you to select out of range values For cold start operation turn the low limit off by pressing the down arrow key repeatedly until OFF is displayed IMPORTANT To p...

Страница 26: ...ncluded in the following pages Those menus are non functional and reserved for future use A Changing the Heat Manager Settings In any mode or screen other than an OPTION sub menu press the OPTION key...

Страница 27: ...s This helps to increase the efficiency of the system by transferring more heat into the home instead of letting it sit in the boiler The circulator on delay holds the C1 output off for the set time a...

Страница 28: ...g diagrams in Figures 11 thru 13 for proper wiring with DHWP on Press CANCEL BACK to exit c 4 1 2 3 4 5 6 E Selecting Fahrenheit or Celsius Temperature Display In any mode other than an OPTION sub men...

Страница 29: ...press ENTER RESET to change Use the and keys to change the setting If DELAY OFF is displayed Press ENTER RESET again the following screen appears Press ENTER RESET to accept the settings or press CAN...

Страница 30: ...tes to give the DHW zone priority If DHWP is set on ZR and there is a ZR call for heat C1 is held off for up to 20 minutes to give the DHW zone priority Once the high limit is reached the burner shoul...

Страница 31: ...until the call for heat is satisfied Low Temperature Limit Adjustable 100 to 220 F Starts the burner at LOW LIMIT set point Low Temperature Differential Adjustable 10 to 45 F Shuts burner off when tem...

Страница 32: ...omponent failures power outages or other electrical system failures could result in frozen plumbing and water damage in a matter of hours For protection take preventative actions such as having a secu...

Страница 33: ...ning properly by observing at least one complete cycle At shutdown the temperature and pressure level match the recommended settings The pressure relief valve operation and boiler water feed system wo...

Страница 34: ...34 Notes Section...

Страница 35: ...35 AquaSmart Boiler Control Manual SK10029 Mounting Template THIS END UP Use self drilling screws supplied in the 7600RMU Remote Mount Kit or Drill 0 110 diameter holes...

Страница 36: ...py of warranty form 61545 please choose one of the following options Visit our website at www beckettcorp com warranty Email your request to rwb customer service beckettcorp com Write to R W Beckett C...