General Description
Becker Avionics
Technical Data
18
RCU6512
DV17551.03 Issue 03 June 2020
1.8 Technical Data
General Characteristics
RCU6512
Nominal supply voltage
14…28 VDC
Extended supply voltage
9.0...32.2 VDC
Emergency operation voltage (with RT6512) 18...20.5 VDC
Maximum Power Consumption
≤
90 mA
Turn OFF Power Consumption
≤
1 mA
Frequency Range
118.000...155.975 MHz
(depends on RT6512 variant)
Channel Spacing
25 kHz
8.33/25 kHz (up to 136.9916 MHz)
Device protection (internal fuse)
1 A
Dimming control
0…5 V, 0…14 V or 0…28 V
Storage temperature range
-55...+85 °C
Operating temperature range
-20...+55 °C, short-time +70 °C
Operating altitude
35 000 ft
Dimensions & Weight
RCU6512
Specifications
Dimensions HxW
61 x 61 mm (2.4 x 2.4 inch)
Depth of device
65.9 mm (2.59 inch)
Mounting depth
39.3 mm (1.55 inch)
Weight
0.2 kg (0.44 lbs)
Material
AlMg/Plastic
Panel color
Control-head coated black matt
Software
In accordance with EUROCAE/RTCA Document ED-12C/DO-178C the software is specified as:
Design Assurance Level (DAL) "C"
Hardware
The RCU6512 devices do not contain Complex Electronic Hardware (CEH).
Continued Airworthiness
•
The RT6512 maintenance is defined as "on condition" only.
•
No scheduled or regular maintenance of this product is required.