Local operation with a single button
Only use a single button (normally open). Only connect one drive for each push-button.
The length of cable between the tubular drive and the push-button must not exceed 20 m.
The push-button must not be operated during the first five seconds after the mains voltage
has been switched on.
N
L
1
2
3
4
PE
Button (normally open)
Connection
1 = black
2 = brown
3 = blue
4 = green / yellow
Button commands
Operation proceeds in this sequence: "Travel-Stop-Travel-in-
the-opposite-direction-Stop".
< 1 second
Moves in maintained operation
> 1 second
Moves in dead-man mode
Double-tap < 1
second
Moves to the intermediate position (in altern-
ation if both are programmed)
Disposal
The crossed-out bin symbol on the product indicates that the device is subject to mandatory disposal separate from household
waste. This product must be handed over to a collection point for electrical and electronic equipment at the end of its service life.
The packaging material must be disposed of properly.
Maintenance
These drives are maintenance-free.