![Becker E16-V1 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/becker/e16-v1/e16-v1_assembly-and-operating-instructions-manual_2718502012.webp)
Setting the limit positions using the programming unit
black
brown
blue
green-yellow
black
brown
blue
green-yellow
Programming button
Travel button
Unlocked
Locked
Locking bolt
Moving part of the locking system on the front section of the sun protection system
Bolt mechanism
Fixed part of the locking system in the guide track of the sun protection system
Connect the wires of the tubular drive to those of the same colour in the programming unit (Item No. 4935 200 011 0) and switch
on the power supply.
Attention
The tubular drives are designed for short-time operation (S2/KB 4 min). An inbuilt thermal
protection switch prevents overheating of the tubular drive. During commissioning (long
drop distance or long running time), the thermoswitch may trigger. The drive will switch
off. After a short cooling-down period, the system is ready for operation again.
The drive does not achieve its full duty cycle until it has cooled to ambient temperature.
Avoid a situation where the thermal protection switch cuts in repeatedly.
If the tubular drive switches off prematurely while opening, due to an obstruction, the ob-
struction can be cleared by closing the screen and removing the obstruction. The upper
limit position can be set by opening again.
First, press the travel button to retract to the upper limit position, until the tubular
drive switches itself off.
Run the bolt past the locking point and stop the tubular drive. Then press the pro-
gramming button.
▻
The locking limit position is now saved and the tubular drive makes a "click"
sound to confirm.