Changing direction of rotation via master transmitter
Press the or button.
▻
The shading solution runs in the desired direction.
►
The running direction is OK.
If the shading solution runs in the wrong direction, the running direction must be changed. Proceed as follows:
3s
First, press the programming button, then within 3 seconds also press the and
button for 3 seconds.
►
The tubular drive confirms.
Check the running direction again.
Setting the limit positions
Limit position status indicator
A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
Attention
The tubular drives are designed for short-time operation (for the operating mode, please
see technical data). An inbuilt thermal protection switch prevents overheating of the tubu-
lar drive. During commissioning (long drop distance or long running time), the ther-
moswitch may trigger. The drive will switch off. After a short cooling-down period, the sys-
tem is ready for operation again.
The drive does not achieve its full duty cycle until it has cooled to ambient temperature.
Avoid a situation where the thermal protection switch cuts in repeatedly.
The limit positions can only be set with the master transmitter. The shutter direction must
be correct. When setting the limit positions, the tubular drives runs in dead-man mode. If
the tubular drive switches off prematurely while opening, due to an obstruction, the ob-
struction can be cleared by closing the screen and removing the obstruction. The upper
limit position can be set by opening again.
Installation step 1:
First, press the UP button to retract to the upper limit position, until the tubular drive
switches itself off .
Installation step 2:
Run the bolt past the locking point and stop the tubular drive. Now press the pro-
gramming button and also the DOWN button for about 3 seconds. The tubular drive
acknowledges and the locking limit position is saved.
Installation step 3:
Use the UP button to run the bolt in the open direction until it is engaged by the bolt
mechanism. The tubular drive switches off automatically.
12 - en