Becker BXP6402-1R-01 Скачать руководство пользователя страница 1

 

 

 

Becker Avionics GmbH 

 Baden-Airpark B108 

 77836 Rheinmünster 

 Germany  

 +49 (0) 7229 / 305-0 

 Fax +49 (0) 7229 / 305-217  

http://www.becker-avionics.com 

 E-mail: [email protected] 

Remote Controlled 

Transponder 

Mode S Level 2es 

 

BXP6402 

BXP6402-1R-(XX) Class 1 

BXP6402-2R-(XX) Class 2 

 

 

Software Versions: 

 
upwards from Software Version 
DSP: 

SCI1026S305 

Version 47 

FPGA:  SCI1039S305 

Version 55 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation and Operation 

 

Manual 

DV69802.03 

Issue 04 

June 2018 

Article-No.  0584.071-071 

 

 

Содержание BXP6402-1R-01

Страница 1: ...s com E mail info becker avionics com Remote Controlled Transponder Mode S Level 2es BXP6402 BXP6402 1R XX Class 1 BXP6402 2R XX Class 2 Software Versions upwards from Software Version DSP SCI1026S305...

Страница 2: ...Avionics GmbH provide product or system options for further investigation by users having technical knowledge The user is responsible for making the final selection of the system and components The us...

Страница 3: ...evelopment and manufacturing of our product the guidelines for highest quality and reliability have been borne in mind supplemented by selection of high quality material responsible production and tes...

Страница 4: ...69802 03 issue 04 Article Number 0584 071 071 Cover Page 06 2018 Introduction 06 2018 Chapter 1 4 06 2018 Issue Page No Section Chapter Description 04 all all Changed Editorial adjustments Introductio...

Страница 5: ...ity 25 2 3 Mounting Requirements 26 2 3 1 Order of Installation 26 2 3 2 Blind Encoder BE6400 26 2 3 3 Antenna 1A032 26 2 4 Dimensions 27 2 4 1 Transponder BXP6402 XR XX 27 2 4 2 Transponder BXP6402 X...

Страница 6: ...Storage 45 3 1 3 Scope of Delivery 45 3 1 4 Type Plate 45 3 2 Operating with CU6401 Controller 45 3 3 Operating with OEM Controller 45 4 Index 48 List of Figures Figure 1 Type Plate example 25 Figure...

Страница 7: ...er 21 dBW 125 W at antenna foot and 250 W at equipment output altitude up to 50 000 ft aircraft speed 175 kt Class 2 XPDR with transmit power 18 5 dBW 70 W at antenna foot and 140 W at equipment outpu...

Страница 8: ...ay Mode S S Selective Interrogation of the Transponder MTL Minimum Triggering Level ON Transponder ON mode without altitude transmission PAM Pulse Amplitude Modulation PBIT Power on Built In Test PN P...

Страница 9: ...d V Volt mV Millivolt W Watt Inch General Safety Definitions Indicates a hazardous situation which if not avoided will result in death or serious injury Indicates a hazardous situation which if not av...

Страница 10: ...vice except for those described in the manual Make connections to the inputs outputs and interfaces only in the manner described in the manual Fix the devices according to the mounting instructions We...

Страница 11: ...essories 21 The remote controlled Mode S transponder BXP6402 XR XX forms together with a control unit e g CU6401 an airborne component of the Air Traffic Control ATC It works as a Mode S Secondary Sur...

Страница 12: ...manual also contains several optional elements of the system Blind encoder for example that may not be contained in your delivery package and in that case are not applicable For further descriptions w...

Страница 13: ...e EHS Extended squitters transmission Data link capability GPS receiver connection capability ADS B Broadcast Only System Class B0 e g broadcasts following data o Airborne Position Message o Surface P...

Страница 14: ...18 1 3 Variants Overview Within the part number the meaning of XR XX is BXP 6402 X R X X Identifier Model Number Options 01 Standard XPDR Class 1 Class 1 2 Class 2 Design R Remote Controlled 1 3 1 Sof...

Страница 15: ...onnect the unit with reversed polarity to the DC source Circuit breaker If no load is connected to connector P9 pin 6 the unit should be protected from the aircraft power supply by a dedicated 3 A cir...

Страница 16: ...tive External Ident input 0 active 3 5 V 1 not active 4 0 V Isource shorted to GND 10 mA Ground detection input ground 0 5 V airborne 2 V Isource shorted to GND 10 mA Power up time 2 s including inter...

Страница 17: ...ate capability Mode A C at least 1200 Mode A C replies s for a 15 pulse coded reply can be limited to 500 1200 Mode S at least 50 Mode S replies s interval thereof at least 16 long formats Mode S squi...

Страница 18: ...n mode S DPSK Differential Phase Shift Keying Side lobe suppression 3 pulse method mode A C P5 mode S Nominal impedance 50 1 6 4 Dimensions Weight Specifications BXP6402 XR XX Front plate HxW 61x61 mm...

Страница 19: ...to 95 humidity at 50 C Shock and Crash Safety 7 0 B Equipment tested to Category B Vibration 8 0 S U Cat S vibration test curve M Cat U vibration test curve G Explosion Proofness 9 0 X No test perform...

Страница 20: ...B Level C In accordance with EURO CAE RTCA ED 14D DO 160D Operating altitude 50 000 ft max class 1 15 000 ft max class 2 In flight loss of cooling Cat Z no auxiliary cooling required Humidity Cat A 50...

Страница 21: ...altitude encoder 1 BE6400 1 01 Article No 0592 137 915 Qty Antenna 1 1A032 Transponder antenna KEC KC 89 BNC Article No 0707 007 952 Qty Mounting kit for BXP6402 1 Mounting kit MK4401 Article No 0556...

Страница 22: ...0551 732 277 1 TNC coaxial connector for RG 58C U soldering Article No 0552 781 277 1 BNC antenna connector for RG 58C U crimp Article No 0551 708 277 1 BNC antenna connector for RG 223 U crimp Artic...

Страница 23: ...6400 26 2 3 3 Antenna 1A032 26 2 4 Dimensions 27 2 4 1 Transponder BXP6402 XR XX 27 2 4 2 Transponder BXP6402 XR XX with Mounting Kit MK4401 28 2 4 3 Address Module AM6400 1 01 29 2 4 4 Blind Encoder...

Страница 24: ...device First Device Checkup Check the device for signs of transport damages Please verify if the indications on the type plate correspond to your purchase order Check if the equipment is complete Sco...

Страница 25: ...Compliance and Certifications Corresponding to the displayed text and logos 2 2 4 Software Firmware Status Functionality The implemented firmware version can be checked with the control unit With con...

Страница 26: ...nd Encoder BE6400 For installation of the Becker Avionics Blind Encoder BE6400 the corresponding manual has to be noticed BE6400 I O manual Article No 0594 547 071 The Blind Encoder BE6400 is intended...

Страница 27: ...ponder BXP6402 XR XX Center of Gravity without address module Allowable deviation for dimensions without tolerances DIN ISO 2768 T1 C xx 6 0 3 30 120 0 8 400 1000 2 0 6 30 0 5 120 400 1 2 1000 2000 3...

Страница 28: ...enter of Gravity without address module Allowable deviation for dimensions without tolerances DIN ISO 2768 T1 C xx 6 0 3 30 120 0 8 400 1000 2 0 6 30 0 5 120 400 1 2 1000 2000 3 0 CENTER OF GR AVITY 2...

Страница 29: ...ssue 04 June 2018 BXP6402 29 2 4 3 Address Module AM6400 1 01 Dimensions mm inch Figure 4 Address Module AM6400 1 01 2 4 4 Blind Encoder BE6400 Dimensions mm inch Figure 5 Blind Encoder BE6400 46 4 1...

Страница 30: ...Installation Dimensions 30 BXP6402 DV69802 03 Issue 04 June 2018 2 4 5 Antenna 1A032 Dimensions mm inch Figure 6 Antenna 1A032...

Страница 31: ...o connector P9 pin 6 the circuit breaker should be a 5 A type Address module The programming of the address module AM6400 1 with the ICAO 24 bit address of the aircraft must be carried out only at an...

Страница 32: ...timeter parallel interface BXP6402 AWG24 GPS Enable aircraft DC supply ground AWG26 3 A4 Altitude A4 encoding altimeter parallel interface BXP6402 AWG24 4 IDENT_N IDENT button external external IDENT...

Страница 33: ...4 Encoding altimeter parallel interface BXP6402 AWG24 20 D4 Altitude D4 Encoding altimeter parallel interface BXP6402 AWG24 21 TX RS422 interface BXP6402 CU6401 AWG26 22 TX RS422 interface BXP6402 CU6...

Страница 34: ...02 AWG26 twisted pair shielded all together 15 TISRX RS422 data interface Avionics Data Link Processor BXP6402 AWG26 twisted pair shielded all together 16 Not connected 17 TISTX RS422 data interface B...

Страница 35: ...The suppression pulses may not be compatible with all models of DME In this case leave the suppression pin open e g P9 pin 5 In cases when the DME has only a suppression output e g Bendix King KN62 KN...

Страница 36: ...equest or by means of the extended squitter function In both cases the valid information must be available in the GICB registers in the transponder The transponder also transmits information by means...

Страница 37: ...craft supply when the BXP640X is switched ON the output voltage P9 pin6 corresponds to the supply voltage P9 pin11 12 The equipment is capable to operate with following certified GPS receivers FreeFli...

Страница 38: ...f control functions and indications o Use another device e g FMS Two interfaces are available for that purpose o RX TX on connector P9 of the transponder The transponder accepts and transmits only con...

Страница 39: ...Store button STO ALTM SELECT GARMIN TRIMBLE NORTHSTAR UPS AT BECKER BE6400 UPS AT LORAN MAGELLAN SHADIN ARNAV store store store store store store store PARALLEL default store DIMMING INPUT None set i...

Страница 40: ...eep in your mind the listed failures and delete the latches with the Clear Latch store sequence 2 8 Aircraft Wiring Installation of the unit varies according to aircraft and equipment design It is the...

Страница 41: ...D SWITCH GND TISRX TISRX TISTX TISTX 1 1 PSEL GND GND BXP6402 grounding screw AWG16 Address Module AM6400 P9 J8 J6 J7 connection to shell connection to shell 2xAWG20 6 7 TX Supply TX GND GPS receiver...

Страница 42: ...ND TISRX TISRX TISTX TISTX 1 1 PSEL GND GND BXP6402 grounding screw AWG16 Address Module AM6400 P9 J8 J6 J7 connection to shell connection to shell 2xAWG20 12 13 TX TX GND 12 13 ALTS ALTS 8 9 8 9 RX 2...

Страница 43: ...for BE6400 2 8 4 BXP6402 with RS232 GPS Receiver Cutout Figure 11 BXP6402 RS232 GPS Receiver Connection not with BE6400 If the blind encoder BE6400 is directly connected to J8 it is not possible to c...

Страница 44: ...case of a fault appears the report FAILURE in the display Switch OFF the transponder at the fault indication 2 9 2 Check of the Address Module The installation company has to make sure that the corres...

Страница 45: ...ol to locate identify and track aircraft BXP6402 is a remote controlled transponder and needs an additional controlling device For further information about Interface and protocol refer to the documen...

Страница 46: ...Operating Instructions Operating with OEM Controller 46 BXP6402 DV69802 03 Issue 04 June 2018 Blank Page...

Страница 47: ...Operating Instructions Operating with OEM Controller DV69802 03 Issue 04 June 2018 BXP6402 47 Blank Page...

Страница 48: ...cription 11 Grounding 31 Installation 23 List of Abbreviations 7 Mounting 26 Non Warranty Clause 10 Operation Instructions 45 Packaging transport storage 24 Purpose of Equipment 13 Safety Definitions...

Отзывы: