background image

Type

L80/11C

PS(+)SMI

L80/17C

PS(+)SMI*

L120/11C

PS(+)SMI

Rated torque [Nm]

80

80

120

Output speed [rpm]

11

17

11

Limit switch range

64 revolutions

Supply voltage

230 V AC / 50 Hz

Connected load [W]

310

470

435

Rated current con-
sumption [A]

1.40

2.10

1.90

Mode

S2 4 min

Degree of protection

IP 44

Min. tube inside dia-
meter [mm]

60

Emission sound pres-
sure level [dB(A)]

≤ 70

*) This tubular drive is not yet available.

Sample wiring diagram

Controlling one/several drive(s) via a single KNX/SMI actuator

Central control of up to 8 drives possible

Button operation is activated by turning the power supply on and off.

The drive permanently changes to SMI mode as soon as SMI bus voltage is detected on the

I+ and I- lines.

Technical information as well as the KNX product database can be found on our homepage www.becker-antriebe.com

21

Содержание L120/11C PS(+)SMI

Страница 1: ...structions SMI Rohrantriebe Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebe...

Страница 2: ...ing the drive adapter with drive adapter safety catch 9 Assembling the drive adapter with screw connection 9 Securing the drive against axial displacement 9 Fixing the drive adapter to the barrel dia...

Страница 3: ...SMI actuators made by the drive manufacturer For plug in connecting cable PS SMI Optimised for sun protection applications Installation without stops is possible from extended point to retracted point...

Страница 4: ...cialists in particular qualified electricians Children from the age of 8 years and persons with reduced physical sensory or mental capabilities or lack of experience and or knowledge may use these dev...

Страница 5: ...er surface from which access to the drive is gained To ensure safe operation of the system after commissioning the limit positions must be correctly set programmed in Drives with a H05VV F connecting...

Страница 6: ...s at the same time The type of tubular drive has been designed particularly for the operation of cassette awnings with a higher requirement for closing torque clean closure of the cassette For roller...

Страница 7: ...he two plug grooves provided for this purpose Check that the cable is properly engaged 1 locating lug Disassembling the plug in connecting cable for tubular drives dia 35 Caution Prior to disassembly...

Страница 8: ...fitter must ensure that the masonry and the system being motorised are sufficiently robust drive torque plus weight of the shading solution Caution Electrical connections may only be carried out by a...

Страница 9: ...drive adapter 1 onto the drive shaft of the tubular drive You can see which way to insert the safety catch 2 from its shape When inserting the drive adapter safety catch 2 into the hole 4 make sure th...

Страница 10: ...n the tube For profile tubes In the case of some drive adapters tolerances of the groove widths in different bar rels can be offset by rotating the drive adapter into a different groove recess These g...

Страница 11: ...s Attention If the allocation table for the SMI tubular drives is incorrect or not available commission ing of the KNX SMI actuator is not possible Connection to the programming unit green yellow blue...

Страница 12: ...been set It may be necessary to delete both limit positions in order to change the direction of rotation There are 4 ways to set the limit positions Lower point to upper point not the stops Lower poin...

Страница 13: ...sound to confirm The limit positions are now set Lower point to upper stop Close to the desired lower limit position Press the programming button of the programming unit for 3 seconds The tubular driv...

Страница 14: ...t be switched Proceed as follows Switch the direction switch 1 to the opposite position The running direction will now have changed Check the running direction again It is only possible to change the...

Страница 15: ...to the desired retracted limit position Press the programming button of the programming unit for 3 seconds The tubular drive makes a click sound to confirm The limit positions are now set Extended pos...

Страница 16: ...n sequence Deleting a limit position when 2 limit positions are programmed green yellow blue brown black grey green yellow blue brown black grey Programming button Travel button Open close to the limi...

Страница 17: ...he programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button but continue to keep the travel button pressed Next press the program...

Страница 18: ...imit position and retract immedi ately Tubular drive stops arbitrarily cannot be restarted in the same direction Tubular drive is overloaded Use a more powerful tubular drive Sun protection system kee...

Страница 19: ...system The changeover time for switching the running direction must be at least 0 5 s The switch and control must not execute simultaneous UP and DOWN com mands Protect the electrical connections from...

Страница 20: ...current con sumption A 0 45 0 50 0 75 0 90 1 18 1 10 Mode S2 4 min Degree of protection IP 44 Min tube inside dia meter mm 47 Emission sound pres sure level dB A 70 Technical data dia 58 Type L50 17C...

Страница 21: ...eter mm 60 Emission sound pres sure level dB A 70 This tubular drive is not yet available Sample wiring diagram Controlling one several drive s via a single KNX SMI actuator Central control of up to 8...

Страница 22: ...stallation Direction of rotation as signed limit positions pro grammed Manufacturer s code 2 Becker Antriebe GmbH Project customer Room Signature Project manager building contractor Signature Installi...

Страница 23: ...Declaration of conformity 23...

Страница 24: ......

Отзывы: