Adjusting the PR+SMI limit positions
Check the assignment of the direction of rotation before positioning the limit stops.
Press the UP or DOWN button
▻
The shading solution runs in the desired direction.
►
The running direction is OK.
If the shading solution runs in the wrong direction, the running direction must be switched. Proceed as follows:
Switch the direction switch (1) to the opposite position.
►
The running direction will now have changed.
Check the running direction again.
It is only possible to change the direction of rotation if no limit position has been set. It may
be necessary to delete both limit positions in order to change the direction of rotation.
There are 4 ways to set the limit positions:
•
Lower point to upper point (not the stops)
•
Lower point to upper stop
•
Anti-lifting device in the lower limit position to upper stop
•
Anti-lifting device in the lower limit position to upper point without stop (only with the programming unit)
The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times.
If the tubular drive switches off prematurely while opening or closing, due to an obstruc-
tion, the obstruction can be cleared by reversing a short way and removing the obstruc-
tion. The desired limit position can be set by opening/closing again.