background image

Rev 1   

Copyright © 2021 by BECCA Inc. All Rights Reserved.

                                                                    BECCA 55 Gal Recycler Operator

’s Guide Poster   

OPERATORS GUIDE 

          

 

 
 
 

1) Safety 

 

Before operating the BECCA SOLVENT SAVER™, read the Instruction Manual completely. All BECCA products are 
engineered and manufactured to the highest performance standards and have been subjected to detailed testing before 
shipment from the factory.

 

                                DANGER LABELS (1- 4)                                                                                WARNING LABELS (5 

– 8) 

            

               2 

                3                       4

                                                      5                           6 

             7                          8 

 

1.   Presence of flammable vapors and solvents.    4.  Wear Breathable  Air during use                   7.   Wear solvent-proof rubber gloves.  

2.  No smoking or metal grinding in area. 

  5.  Observe warnings at all times.                      8.   Wear protective eye wear before use  

3.  Keep away from open flames. 

  6.  Read the Instruction Manual carefully. 

       

 
WARNING!

  

Read the Instruction Manual to become familiar with all aspects of the equipment.

 

 

2) Operation 

 

 

1.  Before filling the Recycler, place a new Recycler Bag in the Tank.   Fold 

the excess bag material down over the ring.  Be sure to keep the bag 
clear of the loading fitting. 

 
2.  Turn the Unloading Valve on the Recycler and pump used solvent waste 

into Recycler 2 to 3 inches below top of the basket. 

  
 
3.  Pour Paint waste into Recycler 

– Make sure to stir waste paint in Recycler 

bag to dilute the concentration. 

 

 

 Add no more than 16 Gallons of paint solids to a 55 gal unit or 
there will be efficiency losses.      

 

Caution! 

 Larger amounts of Paint Solids will reduce the capabilities of the unit.  

                

This is due to the large heat sink created by the excess solid material. 

 
 

 
4.  The system will initially be set at 350 ºF for 6 hours at 100% power. Adjustments 

(see Instruction Manual) to the time may be required depending on the types of 
solvents, type of paint, the painter’s waste levels, and the desired consistency of 
the Waste material. 
 

5.  Assure there is an empty metal container under the tube coming from the 

Condenser.  
 

 

 

             

             

WARNING!

 

Make sure the ground strap is attached.

 

 
 

 