6
EXCHANGING GOBOS
WARNING!
Turn the unit off, disconnect mains power supply and let the unit cool down
sufficiently before you will start with inserting or exchanging gobo’s .
If you wish to use other patterns as the standard-gobos, make sure that the gobo which you want to insert
or exchange has exactly the same size, please follow the instructions below:
•
Remove the spring with an appropriate tool.
•
Remove the gobo and insert the new gobo.
•
Press the spring together and insert it in front of the gobo.
Glass gobo
Coated glass gobos are inserted with the coating against the rim of the holder (away from the spring).
Textured gobo’s are inserted with the smooth side against the spring.
GOBO DIMENSIONS
Outer Diameter (O.D)
: 24.8mm
Image Diameter (I.D)
: 21mm
Max. thickness
: 1.1 mm
CLEANING
The buildup of dust, dirt and other airborne particles will reduce the unit’s light output. It will also prevent the unit from cooling correctly, and this will
reduce the unit’s lifetime. The rate of dirt buildup will vary depending on environmental factors such as airborne dust, use of smoke machines, airflow
from ventilation systems, etc. The unit’s cooling fans will accelerate buildup, and any smoke particles that are present in the atmosphere will increase
the tendency for dirt to clog.
To get the best performance and lifetime from the unit, inspect it regularly and clean it as soon as you see signs of dirt buildup.
Assess the operating environment each time you begin to use the unit. In dusty or smoky conditions, inspect the unit after a few hours and check it
frequently the unit may attract dirt faster than you expect. Draw up a cleaning schedule that will make sure that dirt is removed before it can build up.
Use the following guidelines:
•
Disconnect the unit from power and allow it to cool completely before cleaning.
•
Do not use solvents, abrasives or any other aggressive product to clean the unit.
•
Vacuum or use low-pressure compressed air to remove dust and loose particles from surfaces and air vents. Prevent the blades of cooling fans
from turning before you aim a vacuum or air jet at the fan, or you may spin the fan too fast and damage it.
•
Clean glass components by wiping gently with a soft, clean, lint-free cloth moistened with a weak detergent solution. Put the solution on the
cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces.
•
Dry the unit with a soft, clean, lint-free cloth or low-pressure compressed air before reapplying power.
REPLACING THE FUSE
If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.