If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first unit in a DMX chain.
Always connect the output of one unit with the input of the next unit until all units are connected.
Caution: At the last unit, you must close the DMX line with a terminating resistor. Take an XLR connector and solder a 120 Ohm resistor
between signal (-) and signal (+) and connect it to the DMX output of the last unit in the line.
DMX CHANNELS
Channel
Function
Value
Description
1
Fan
000-255
Fan speed, from low to high
We recommend a frequent cleaning of the unit from the outside to remove contaminants such as dust etc.
Noted: There are no serviceable parts inside the unit except for the fuse. Repairs and service operations are only to be carried out by authorized
dealers.
CAUTION! Disconnect the mains plug from the wall socket before starting any maintenance work!
•
Ensure the air vents are not clogged by dust. If necessary remove the dust.
•
Ensure that the unit can not get overheated.
•
Clean the surfaces with a lint-free, damp cloth. Never use alcohol or other solvents, otherwise the surface of the housing may be damaged.
•
Do not allow any moisture or moisture to enter the unit.
•
The unit must be dry before switching it on again.
If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.