background image

 

 

CAUTION! Immediately upon receiving the product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been 
received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damage from shipping or the 

package itself shows signs of mishandling. Save the package and all packing materials. In the event that the product must be returned to the factory, it 
is important that the product be returned in the original factory box and packing. 

 

If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation 
water might damage your unit. Leave the unit switched off until it has reached room temperature. 

On the label on the backside of the unit is indicated on this type of power supply must be connected. Check that the mains voltage corresponds to this, 

all other voltages than specified, the light effect can be irreparably damaged. The product must also be directly connected to the mains and may be 
used. No dimmer or adjustable power supply. 

 

Always connect the unit to a protected circuit (circuit breaker or fuse). Make sure the unit has an appropriate electrical ground to avoid the 
risk of electrocution or fire. 

Step 1: Place the unit on a flat surface and in a suitably large area with at least 50 cm of open space around the 

unit.  
Step 2: Do not orientate the escape nozzle directly in the direction of the audience's eyes. 
Step 3:To adjust the output angle, release the fixation screw, adjust the desired angle and retighten the fixation 
screw.  
Step 4: Connect the DMX via 3pin XLR cable and plug the mains plug into a wall socket. 

Step 5: Turn on the unit, put the power switch to the 

O

N”

 position. The LCD display will show 

WARMING UP

After few seconds the LCD display will shows 

READY

Step 6: Adjust the settings via LCD display. 
Step 7: Fill the unit with loose confetti (accessory). 

 

When display shows “READY”, 

you can start producing haze and adjust the settings via LCD display panel. 

 

Menu 

Description 

Man Vol Out xxx% 

Adjust the manual volume output within the range of 0% to 100% by means 
of the Up/Down keys. 

Interval Set xxxS 

Adjust the interval between 1 to 100S by means of the Up-/Down keys. 

Duration Set xxxS 

Adjust the duration between 1 to 100S by means of the Up-/Down keys.. 

Volume Out xxx% 

Adjust the volume output within the range of 0- 100% by means of the Up-
/Down keys. 

DMX 512 #xxx 

Adjust the DMX address for DMX control by means of the Up-/Down keys. 

Wind For Class xx 

Adjust the wind output during the function within the range of 0- 100% by 
means of the Up-/Down keys. 

Angel Set xx% 

No function for this model. 

Wireless 

Turn on/off wireless remote. 

 
W IRELESS REMOTE 

A: ON / OFF 
B: ON / OFF 
C: Output volume up 

D: Output volume down 
 

Содержание CC1200 CONFETTI

Страница 1: ...CC1200 CONFETTI 160 762 V1 0...

Страница 2: ...PANNING 7 INSTALLATIE 7 BEDIENING 7 DMX BEDIENING 8 REINIGEN 8 VERVANGEN ZEKERING 8 DEUTSCH SICHERHEITSHINWEISE 9 AUSPACKEN 10 NETZANSCHLUSS 10 INSTALLATION 10 BEDIENUNG 10 DMX BEDIENUNG 11 REINIGUNG...

Страница 3: ...ION 16 FONCTIONNEMENT 16 GESTION DMX512 17 NETTOYAGE 17 REMPLACEMENT DU FUSIBLE 17 POLSKI INSTRUKCJA BEZPIECZE STWA 18 ROZPAKOWYWANIE INSTRUKCJI 19 ZASILACZ 19 INSTALACJA 19 DZIALANIE 19 KONTROLA DMX5...

Страница 4: ...persons with epilepsy This unit is not designed for permanent operation Consistent operation breaks will ensure that the unit will serve you for a long time without defects CAUTION If the power cord o...

Страница 5: ...ce the unit on a flat surface and in a suitably large area with at least 50 cm of open space around the unit Step 2 Do not orientate the escape nozzle directly in the direction of the audience s eyes...

Страница 6: ...he unit except for the fuse Repairs and service operations are only to be carried out by authorized dealers CAUTION Disconnect the mains plug from the wall socket before starting any maintenance work...

Страница 7: ...personen of personen met epilepsie Dit apparaat is niet ontworpen voor permanent gebruik Consistente bedieningspauzes zullen ervoor zorgen dat het apparaat lang zonder defecten van dienst zal zijn WAA...

Страница 8: ...ak met minstens 50 cm open ruimte rondom het apparaat Stap 2 Richt het uitlaatmondstuk niet direct in de richting van de ogen van het publiek Stap 3 Om de hoek aan te passen draait u de bevestigingssc...

Страница 9: ...rden uitgevoerd door geautoriseerde dealers WAARSCHUWING Haal de netstekker uit het wandcontactdoos voordat u met onderhoudswerkzaamheden begint Zorg ervoor dat de ventilatieroosters niet verstopt rak...

Страница 10: ...iebspausen wird sichergestellt dass das Ger t lange Zeit st rungsfrei arbeitet WARNUNG Wenn das Netzkabel des Ger ts mit einer Erdungsklemme ausgestattet ist schlie en Sie es an eine Steckdose mit ein...

Страница 11: ...t mindestens 50 cm freier Fl che um das Ger t herum Schritt 2 Richten Sie die Austrittsd se nicht in Augenh he des Publikums Schritt 3 Um den Ausgangswinkel einzustellen l sen Sie die Befestigungsschr...

Страница 12: ...Sie vor Beginn der Wartungsarbeiten den Netzstecker aus der Steckdose Stellen Sie sicher dass die L ftungs ffnungen nicht durch Staub verstopft sind Bei Bedarf den Staub entfernen Stellen Sie sicher d...

Страница 13: ...es epil pticos en personas fotosensibles o personas con epilepsia Esta unidad no est dise ada para una operaci n permanente Las interrupciones constantes de la operaci n garantizar n que el dispositiv...

Страница 14: ...rea adecuadamente grande con al menos 50 cm de espacio abierto alrededor de la unidad Paso 2 No oriente la boquilla de escape directamente en la direcci n de los ojos del p blico Paso 3 Para ajustar...

Страница 15: ...es y las operaciones de servicio solo deben ser realizadas por distribuidores autorizados PRECAUCI N Desconecte el enchufe de la toma de corriente de la pared antes de iniciar cualquier trabajo de man...

Страница 16: ...d clencher des crises d pilepsie chez les personnes photosensibles ou pileptiques Cet appareil n est pas con u pour fonctionner en permanence Des pauses d utilisation r guli res assureront un fonctio...

Страница 17: ...d incendie Etape 1 Placez l appareil sur une surface plane et dans une zone suffisamment large avec 50 cm d espace au moins autour de l appareil Etape 2 N orientez pas la buse directement vers les yeu...

Страница 18: ...areil ne demande une intervention ext rieure Les r parations ou op rations de maintenance ne doivent tre effectu es que par un r parateur agr ATTENTION D branchez imp rativement l appareil du secteur...

Страница 19: ...ch lub z padaczk To urz dzenie nie jest przeznaczone do ci g ej pracy Sp jne przerwy w dzia aniu zapewni e urz dzenie b dzie s u y przez d ugi czas bez wad UWAGA Je li przew d zasilaj cy urz dzenia je...

Страница 20: ...zne aby unikn ryzyka pora enia pr dem lub po aru Krok 1 Umie urz dzenie na p askiej powierzchni i na odpowiednio du ym obszarze z co najmniej 50 cm wolnej przestrzeni wok urz dzenia Krok 2 Nie ustawia...

Страница 21: ...ci serwisowe mog by wykonywane wy cznie przez autoryzowanych sprzedawc w UWAGA Przed rozpocz ciem jakichkolwiek prac konserwacyjnych od czy wtyczk sieciow od gniazdka ciennego Upewnij si e otwory wen...

Страница 22: ...5 x 510mm Weight per unit 6 4 kg Design and product specifications are subject to change without prior notice The products referred to in this manual conform to the European Community Directives to wh...

Страница 23: ......

Страница 24: ...rs a wide range of high performance lighting equipment and related accessories for the rental entertainment and architectural lighting markets BeamZ Pro stands for performance innovation and value pri...

Отзывы: