Beam 17R Скачать руководство пользователя страница 1

USER MANUAL 

Table of Contents 

Safety Information……………………………………………………...3 

Specifications…………………………………………………………...4 

Main Power Connection……………………………………………….5 

DMX-512 Connection……………………………..…………………...5 

Main Control Menu……………………………………………………..6 

DMX Profile.....................................................................................8 

Rigging the Fixture……………………………………………………10 

Cleaning & Maintenance...............................................................11 

Parts List.......................................................................................11 

Содержание 17R

Страница 1: ...R MANUAL Table of Contents Safety Information 3 Specifications 4 Main Power Connection 5 DMX 512 Connection 5 Main Control Menu 6 DMX Profile 8 Rigging the Fixture 10 Cleaning Maintenance 11 Parts List 11 ...

Страница 2: ......

Страница 3: ...unit movement 6 Maximum surface operating temperature 114º Protection Against Fire 1 Disconnect power before lamp replacement or servicing 2 For connection to main power supply proceed to page 6 3 This unit must be earthed electronically grounded 4 Unit is IP rated 54 do not expose unit to high pressure water or submerge fixture Protection Against Mechanical Hazards 1 Use safety chain when hanging...

Страница 4: ...0 F Fastening System 2 Quick Release Clamp Mounts Ip Rated Ip44 Electrical Specifications Power supply Auto Switch100V 240V 50 60 HZ Color Temp 8000K Power consumption Amps 3 65 Watts 440 Ballast Electronic LAMP YODN 1 7R lamp 330W Display LCD Display 18 75 with handles 10 33 7 5 21 28 50 Prism 8 Facet prism rotating in both directions at different speeds Dimmer Dual Blade dimming Shutter Mechanic...

Страница 5: ...lel Only use a shielded twisted pair cable designed for RS 485 and 3 pin XLR plugs and connectors in order to connect the con troller with the fixture or the fixture with another Caution At the last fixture the DMX signal needs to be terminated with a terminator Solder a 120 Ohm resistor between the and the signal into a 3 pin XLR plug and plug it in to the last fixture on the signal run Pre manuf...

Страница 6: ...isplay DMX 001 16CH 1 OFF OFF OFF ON KEEP OFF Press Ok use the or to select the desired DMX start Channel Press Ok to confirm the setting DMX Channel must match the start Channel setting in your DMX Controller DMX Address Only One channel option 16Ch Mode available Channel Mode Press Ok use the or to select the desired preprogramed demo programs Press Ok to confirm the setting There are 9 programs...

Страница 7: ...Tilt Encoder Pan Tilt No DMX Signal Display DMX 001 16CH 1 OFF OFF ON KEEP OFF Run Mode DMX Address Channel Mode Demo Mode Invert Tilt Swap Pan Tilt Encoder Pan Tilt No DMX Signal Display DMX 001 16CH 1 OFF OFF ON KEEP OFF Run Mode DMX Address Channel Mode Demo Mode Invert Tilt Swap Pan Tilt Encoder Pan Tilt No DMX Signal Display DMX 001 16CH 1 OFF OFF ON KEEP OFF Run Mode DMX Address Channel Mode...

Страница 8: ... 70 74 0 Pink Yellow 75 79 Yellow 80 84 Yellow Magenta 85 89 Magenta 90 94 Magenta Cyan 95 99 Cyan 100 104 Cyan CTO 260 105 109 CTO 260 110 114 CTO 260 CTO 190 115 119 CTO 190 120 124 CTO 190 CTB 8000 125 129 CTB 8000 130 134 CTB 8000 Blue 135 139 Blue 140 144 Blue White 145 149 Color Rotation Slow to Fast 128 255 Closed 0 3 Strobe Slow to Fast 4 103 Open 104 107 2 Shutter Strobe Pulse Slow to Fas...

Страница 9: ...o Fast 186 190 Gobo 5 Shake Slow to Fast 191 195 Gobo 6 Shake Slow to Fast 196 200 Gobo 7 Shake Slow to Fast 201 205 Gobo 8 Shake Slow to Fast 206 210 Gobo 9 Shake Slow to Fast 211 215 Gobo 10 Shake Slow to Fast 216 220 Gobo 11 Shake Slow to Fast 221 225 Gobo 12 Shake Slow to Fast 226 230 Gobo 13 Shake Slow to Fast 231 235 Gobo 14 Shake Slow to Fast 236 240 Gobo 15 Shake Slow to Fast 241 245 Gobo ...

Страница 10: ... injures if you have doubts concerning the safety do not install 3 Unit is to be 24inches away from flammable materials decoration material 4 Use high quality installation equipment to hang unit When rigging a unit it is very important that you follow common safety procedures Rigging requires extensive experi ence including but not limited to calculating working loads material being used and perio...

Страница 11: ...more periodic cleaning as fog fluid tends to build up residues reducing the light output 2 The cooling fans should be cleaned monthly DO NOT blow high pressure air into fans as incorrect rotation can damage the fans operation 3 The gobos dichroic color filters and internal lenses may be cleaned with soft brush using soapy water 4 The interior of the fixture should be cleaned using a vacuum 5 We re...

Страница 12: ...epaid by MSI via the most economical means of shipment Repair or replacement as provided for under this warranty is the exclusive remedy of the consumer MEGA SYSTEMS INC makes no warranties express or implied with respect to any product and Mega Systems specifically disclaims any warranty of merchantability or fitness for a particular purpose Mega Systems shall not be liable for any indirect inci ...

Отзывы: