TECHNICAL SPECIFICATIONS

DESCRIPTION

ENGLISH

UNIDIRECTIONAL OPENING SENSOR 

FOR AUTOMATIC INDUSTRIAL 

DOORS*

1. 

cover

2. 

main connector

3. 

radar antenna

4. 

DIP-switch

5. 

push buttons

Technology:
Transmitted frequency:  
Transmitted radiated power:
Transmitted   power density:
Detection mode:
Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output: 
   Max. contact voltage:
   Max. contact current:
   Max. switching power:
Mounting height: 
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Material:
Weight:
Cable lenght:
Conformity:

microwave
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm²
motion
5 cm/s (measured in the sensor axis)
12V to 24V AC ±10%; 12V to 24V DC +30% / -10%
50 to 60 Hz
< 2 W
relay (free of potential change-over contact)
42V AC - 60V DC
1A (resistive)
30W (DC) / 60VA (AC)
from 2 m to 6 m 
IP64
from -30 °C to + 60 °C
140 mm (L) x 55 mm (H) x 57 mm (W)
0° to 90° vertical; -120° to +120° lateral
ABS
165 g
10 m
RED 2014/53/EU ; 2011/65/EU

Th

is u
se

r’s g
uid

e i

s a
n i

nf

or

m

at

ive d
o

cu

m

en

t a

nd 

ca

n n
ot b
e s
ee

n a
s a c

om

m

itm

en

t o
f r

es

ult

.

Содержание Sparrow

Страница 1: ...ltage Mains frequency Max power consumption Output Max contact voltage Max contact current Max switching power Mounting height Degree of protection Temperature range Dimensions Tilt angles Material Weight Cable lenght Conformity microwave 24 150 GHz 20 dBm EIRP 5 mW cm motion 5 cm s measured in the sensor axis 12V to 24V AC 10 12V to 24V DC 30 10 50 to 60 Hz 2 W relay free of potential change over...

Страница 2: ...rew 3 Slide the sensor on the clip Before fixing After fixing Drill 2 holes using the mounting template Fix the sensor firmly to avoid vibrations TIPS Drill a hole for the cable and pull tinned through towards the sensor Connect the wires accordingly Pass the cable through the opening 180 or use one of the cable conduits Avoid using the one at the top to ensure waterproofness Avoid proximity to ne...

Страница 3: ... way detection towards sensor uni AWAY one way detection away from sensor A active output NO contact P passive output NC contact bi uni uni AWAY FACTORY VALUES normal high Adjust the lateral antenna angle Adjust the vertical antenna angle If mounting height 4 5 m activate BOOST function by DIP switch Mounting height 4 m Boost function OFF Factory values Mounting height 6 m Boost function ON Factor...

Страница 4: ...r motion The sensor needs an access code to unlock Batteries in the remote control are weak or installed improperly It rains and the sensor detects for no apparent reason The sensor detects the motion of the rain drops Remote control badly pointed Check the output configuration setting on each sensor connected to the door operator Verify wiring Make sure the sensor is fixed properly Make sure the ...

Отзывы: