background image

SEAGLE ONE

1

3

5

2

4

Specifications are subject to changes without prior notice.
Measured in specific conditions

TECHNICAL SPECIFICATIONS

DESCRIPTION

ENGLISH

UNIDIRECTIONAL OPENING SENSOR

FOR AUTOMATIC DOORS

1. 

main connector

2. 

potentiometer for field size adjustment

3. 

radar antenna (narrow field)

4. 

DIP-switch

5. 

cover

Technology:
Transmitter frequency:  
Transmitter radiated power:
Transmitter power density:
Detection mode:
Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output: 
   Max. contact voltage:
   Max. contact current:
   Max. switching power:
Mounting height: 
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Material:
Weight:
Cable lenght:
Conformity:

microwave doppler radar
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm²
motion
5 cm/s (measured in sensor axis)
12 V to 24 V AC ±10%; 12 V to 24 V DC +30% / -10%
50 to 60 Hz
< 2 W
relay (free of potential change-over contact)
42 V AC/DC
1 A (resistive)
30 W (DC) / 60 VA (AC)
from 1.8 m to 3 m 
IP54
from -20 °C to + 55 °C
120 mm (L) x 80 mm (H) x 50 mm (W)
0° to 90° vertical; -30° to +30° lateral
ABS
165 g
2.5 m
RED 2014/53/EU

Other use of the device is outside the permitted purpose and can not be 
guaranteed by the manufacturer. The manufacturer cannot be held responsible 
for incorrect installations or inappropriate adjustments of the sensor.

Please keep for further use

Designed for colour printing

For pr

oduct version 0100 and mor

e

Th

is u
se

r’s g
uid

e i

s a
n i

nf

or

m

at

ive d
o

cu

m

en

t a

nd 

ca

n n
ot b
e s
ee

n a
s a c

om

m

itm

en

t o
f r

es

ult

.

Содержание SEAGLE ONE

Страница 1: ... Tilt angles Material Weight Cable lenght Conformity microwave doppler radar 24 150 GHz 20 dBm EIRP 5 mW cm motion 5 cm s measured in sensor axis 12 V to 24 V AC 10 12 V to 24 V DC 30 10 50 to 60 Hz 2 W relay free of potential change over contact 42 V AC DC 1 A resistive 30 W DC 60 VA AC from 1 8 m to 3 m IP54 from 20 C to 55 C 120 mm L x 80 mm H x 50 mm W 0 to 90 vertical 30 to 30 lateral ABS 165...

Страница 2: ...ot cover the sensor Avoid vibrations Do not touch electronical parts Wall mounting above sliding or revolving doors Ceiling mounting in front of sliding revolving or swing doors outside of the door motion range OPENING THE SENSOR TIPS APPLICATIONS Mounting on door axis swing doors ...

Страница 3: ... as follows 1 BROWN POWER SUPPLY 2 GREEN POWER SUPPLY 3 WHITE COM 4 YELLOW NO NC FIELD SIZE DIP SWITCH DIP 1 DETECTION MODE DIP 2 OUTPUT CONFIG DIP 3 PRM MODE DIP 1 ON DIP 4 IMMUNITY FILTER bidirectional unidirectional active NO passive NC for PRM normal high normal PRM persons with reduced mobility field size max vertical angle 30 2 2 m 2 2 m MOUNTING WIRING FIELD WIDTH 4 m x 2 m wide 2 m x 2 5 m...

Страница 4: ...ed by the closing of the door or vibrations caused by the door motion The door opens for no apparent reason It rains and the sensor detects the motion of the rain drops Change the output configuration setting on each sensor connected to the door operator Make sure the sensor is fixed properly Make sure the detection mode is unidirectional Increase the antenna angle Increase the immunity filter Red...

Отзывы: