MINI FLY
1
1
1
1
1
Accessories
The door will not open and
LED lights up.
The door will not open and
LED does not light up.
The door opens when
no detection occurs and
closes during detection.
The detection fi eld is
abnormal
Error detection happens
frequently.
MINI FLY
MINI FLY
* MBKT need separate order.
MFCA
MINI FLY UP
Cable 2.5m/4m (optional)
FLY OVER
Masking lens
MBKT *
Screw
The sensor power is off.
The wiring of relay output is
not connected correctly.
The mode of relay output is
incorrect.
The environment is complicated,
and has strong interfering
resource.
The cut of the masking lens is
wrong. The sensor is installed in
wrong position or angle.
Check the wiring and the power supply.
Change the position of dip-switch 2.
Install the sensor in the right way.
Cut out a new lens to meet the required of sensing fi eld size.
Setting dip-switch 1 to ON state, as the strong
interference model.
Check the relay wiring.
TROUBLE SHOOTING
2
+
=
+
+
=
=
Angleur, November 2010
Jean-Pierre Valkenberg, Authorized representative
The complete declaration of conformity is available on our website: www.bea.be
©
BE
A
|
O
rigi
n
a
l ins
tr
u
c
ti
o
n
s
|
69
.06
7
0
BEA | 3rd-5th Floor Tower B / No.10 Jiu Xian Qiao North Road, Chao yang District, Beijing
| T +86 10 57761616 / F +86 10 62628775
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety.
Only trained and qualifi ed personnel may install and setup the sensor.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
Avoid touching any electronic and optical components.
MINI FLY
1. Cover
2. Lens
3. LED
4.
Passive infrared sensor
The most advanced technology in passive
infrared sensor range
Up to 3.5m
-4° to +4°
2.5m (W) ×1.5m (D) mounting height of 2.2m
4.0m (W) ×2.4m (D) mounting height of 3.5m
Movement
Mounting height
:
Mounting angles:
Maximum detection area
:
Detection mode:
Detection speed:
Immunity:
Dimensions of sensor:
Features:
Microprocessor control/ temperature compensation technology/ adjustable installed angle
Electromagnetic compatibility(EMC) according to 89/336/EEC
64mm(W)×41mm(H)×23mm(D)
Power consumption:
Temperature range:
Degree of protection:
Standard output relay:
Max contact voltage
Max contact current
Max switching power
Response time:
Power supply:
Main frequency:
Max 200 ms
12 VDC -10% to 24 VDC+30% /
12 VAC to 24 V AC +/-10 %
50/60 Hz
-30°C to +55°C
IP54
60 V DC/ 42 V AC
1A (resistive)
30W (DC) / 60 VA(AC)
<1W
0.1 to 1.5m/s
Relay hold time:
0.5s/2s
5.
Unplug 5-wire connector
6. Dip-switch
7. Potentiometer
Other use of the device is outside the permitted purpose and can not be
guaranteed by the manufacturer. The manufacturer cannot be held responsible for
incorrect installations or inappropriate adjustments of the sensor.
EN
TECHNICAL SPECIFICATIONS
DESCRIPTION
Specifi cations are subject to changes without prior notice.
All values measured in optimal conditions.
1
1
Cover
5
U
2
5
6
7
4
3